Details
BUY HT7550-2 https://www.utsource.net/itm/p/12606805.html
| Parameter | Symbol | Conditions | Min | Typ | Max | Unit |
|---|---|---|---|---|---|---|
| Input Voltage | VIN | Operating Range | 4.5 | - | 36 | V |
| Output Voltage | VOUT | Fixed | - | 5.0 | - | V |
| Output Current | IOUT | Continuous | - | 1.5 | 2.0 | A |
| Quiescent Current | IQ | No Load | - | 5 | 10 | 渭A |
| Dropout Voltage | VD | IOUT = 2.0A | - | 1.5 | 2.5 | V |
| Line Regulation | - | VIN = 4.5V to 36V | - | 0.5 | - | % |
| Load Regulation | - | IOUT = 0 to 2.0A | - | 0.5 | - | % |
| Ripple Rejection | - | f = 120Hz | - | 70 | - | dB |
| Operating Temperature | TOPR | - | -40 | - | 85 | 掳C |
| Storage Temperature | TSTG | - | -65 | - | 150 | 掳C |
Instructions for Use:
Input Connection:
- Connect the input voltage (VIN) to the input pin of the HT7550-2.
- Ensure the input voltage is within the operating range of 4.5V to 36V.
Output Connection:
- Connect the output pin to the load or circuit requiring a stable 5V supply.
- The maximum continuous output current is 2.0A, with a typical output current of 1.5A.
Ground Connection:
- Ensure a common ground connection between the input and output circuits.
Heat Dissipation:
- For high output currents, ensure adequate heat dissipation to prevent overheating.
- Consider using a heatsink if the device will operate near its maximum current limits.
Capacitors:
- Use appropriate input and output capacitors to stabilize the voltage and reduce ripple.
- Recommended values: 10渭F ceramic or tantalum capacitor on the input and 10渭F ceramic capacitor on the output.
Operating Temperature:
- The device can operate within a temperature range of -40掳C to 85掳C.
- Store the device in an environment where temperatures do not exceed -65掳C to 150掳C.
Protection Features:
- The HT7550-2 includes overcurrent and thermal protection to prevent damage under fault conditions.
Mounting:
- Mount the device on a PCB with proper clearance to avoid short circuits and ensure good thermal performance.
Testing:
- Before final assembly, test the device with a known load to verify proper operation and output stability.
Handling:
- Handle the device with care to avoid static discharge and physical damage.
- Follow standard ESD (Electrostatic Discharge) precautions during handling and installation.
View more about HT7550-2 on main site