Details
BUY G8NB-2S-12VDC https://www.utsource.net/itm/p/12606807.html
Below is the parameter table and instructions for the G8NB-2S-12VDC relay.
Parameter Table
| Parameter | Value |
|---|---|
| Type | SPDT (Single Pole Double Throw) |
| Coil Voltage | 12V DC |
| Coil Current | 30mA |
| Contact Form | 1C (1 Common) |
| Contact Rating | 10A at 250V AC |
| Insulation Resistance | 100M惟 at 500V DC |
| Dielectric Strength | 1500V AC for 1 minute |
| Mechanical Life | 10 million operations |
| Electrical Life | 100,000 operations (resistive load) |
| Operating Temperature | -40掳C to +85掳C |
| Storage Temperature | -40掳C to +125掳C |
| Weight | 10g |
| Dimensions | 17.5mm x 12.2mm x 12.2mm |
Instructions
Installation:
- Ensure that the relay is installed in a clean, dry environment.
- Mount the relay on a flat surface using the provided mounting holes or clips.
- Avoid installing the relay near heat sources or in areas with high humidity.
Wiring:
- Connect the coil terminals to the 12V DC power supply.
- Connect the common (COM) terminal to the circuit you want to control.
- Connect the normally open (NO) and normally closed (NC) terminals as required by your application.
Operation:
- When the coil is energized, the common contact will switch from the normally closed (NC) position to the normally open (NO) position.
- When the coil is de-energized, the common contact will return to the normally closed (NC) position.
Testing:
- Use a multimeter to verify the continuity between the common and normally closed (NC) contacts when the coil is de-energized.
- Energize the coil and verify the continuity between the common and normally open (NO) contacts.
Maintenance:
- Regularly inspect the relay for signs of wear or damage.
- Clean the relay with a soft, dry cloth if necessary.
- Do not use solvents or abrasive materials to clean the relay.
Safety:
- Always disconnect the power supply before performing any maintenance or testing.
- Ensure that the relay is rated for the voltage and current of your application.
- Follow all local electrical codes and safety regulations.
By following these instructions, you can ensure the proper installation, operation, and maintenance of the G8NB-2S-12VDC relay.
(For reference only)View more about G8NB-2S-12VDC on main site