Details
BUY AUPS4067D2-B https://www.utsource.net/itm/p/12606828.html
| Parameter | Symbol | Min | Typ | Max | Unit | Notes |
|---|---|---|---|---|---|---|
| Input Voltage | VIN | 4.5 | - | 14 | V | Operating range for input voltage |
| Output Voltage | VOUT | - | 5 | - | V | Fixed output voltage |
| Output Current | IOUT | - | - | 3 | A | Maximum continuous output current |
| Efficiency | 畏 | - | 92 | - | % | Typical efficiency at nominal conditions |
| Quiescent Current | IQ | - | 2 | - | mA | Quiescent current at no load |
| Dropout Voltage | VDROPOUT | - | 1.2 | - | V | Dropout voltage at maximum load |
| Load Regulation | - | - | 0.5 | - | % | Change in output voltage with load (from 0 to 3A) |
| Line Regulation | - | - | 0.1 | - | % | Change in output voltage with input voltage (from 4.5V to 14V) |
| Ripple and Noise | - | - | 30 | - | mVpp | Output ripple and noise at full load |
| Operating Temperature | TOPR | -40 | - | 85 | 掳C | Operating temperature range |
| Storage Temperature | TSTG | -65 | - | 150 | 掳C | Storage temperature range |
| Thermal Shutdown | TSD | - | 160 | - | 掳C | Thermal shutdown temperature |
| Package Type | - | - | - | - | TO-220 | Package type |
| Pin Configuration | - | - | - | - | - | See pin configuration diagram |
Instructions for Use:
Input Connection:
- Connect the input voltage (VIN) to the input pin. Ensure the input voltage is within the specified range (4.5V to 14V).
- Connect the ground (GND) to the common ground.
Output Connection:
- Connect the output pin (VOUT) to the load.
- Ensure the load does not exceed the maximum output current (3A).
Heat Dissipation:
- The device may require a heatsink if operating at high output currents or in high ambient temperatures.
- Calculate the power dissipation (P = (VIN - VOUT) * IOUT) and ensure it is within safe limits.
Capacitors:
- Place input and output capacitors close to the respective pins to minimize noise and improve stability.
- Recommended values: 10渭F ceramic capacitor on the input and 10渭F ceramic capacitor on the output.
Thermal Management:
- Monitor the operating temperature to ensure it stays within the specified range (-40掳C to 85掳C).
- If the device reaches the thermal shutdown temperature (160掳C), it will automatically shut down to prevent damage.
Storage:
- Store the device in a dry, cool environment within the storage temperature range (-65掳C to 150掳C).
Testing:
- Before connecting to the final application, test the device with a known load to verify proper operation and output voltage.
Safety:
- Always follow proper electrical safety guidelines when handling and testing the device.
- Ensure all connections are secure and insulated to prevent short circuits.
View more about AUPS4067D2-B on main site