IR4428S

IR4428S


Specifications
SKU
12606833
Details

BUY IR4428S https://www.utsource.net/itm/p/12606833.html

Parameter Symbol Test Conditions Min Typical Max Unit
Drain-Source Voltage VDS - - - 60 V
Gate-Source Voltage VGS - -15 - 15 V
Continuous Drain Current ID VDS = 5V, TA = 25掳C - 12 - A
Pulse Drain Current ID(p) VDS = 5V, TC = 25掳C, tp = 10渭s - 36 - A
Total Power Dissipation PTOT TC = 25掳C - - 100 W
Junction Temperature TJ - -55 - 150 掳C
Storage Temperature TSTG - -55 - 150 掳C
Thermal Resistance, Junction to Case R胃JC - - 0.5 - 掳C/W

Instructions for Use:

  1. Mounting and Handling:

    • Ensure that the device is mounted on a heatsink if operating at high power levels.
    • Handle the device with care to avoid damage to the leads or the body.
  2. Gate Drive:

    • Apply a gate-source voltage (VGS) between 10V and 15V for optimal performance.
    • Avoid applying voltages outside the specified range to prevent damage.
  3. Drain-Source Voltage:

    • Ensure that the drain-source voltage (VDS) does not exceed 60V to avoid breakdown.
  4. Continuous and Pulse Current:

    • The continuous drain current (ID) should not exceed 12A at room temperature.
    • For pulse applications, the peak current (ID(p)) can be up to 36A for short durations (10渭s).
  5. Power Dissipation:

    • The total power dissipation (PTOT) should not exceed 100W to prevent overheating.
    • Use appropriate cooling methods such as heatsinks or forced air cooling to manage heat.
  6. Temperature Considerations:

    • The junction temperature (TJ) should be kept below 150掳C.
    • Store the device in an environment where the temperature ranges from -55掳C to 150掳C.
  7. Thermal Management:

    • Monitor the thermal resistance (R胃JC) to ensure effective heat transfer from the junction to the case.
    • Use thermal paste or other thermal management materials to enhance heat dissipation.
  8. Electrostatic Discharge (ESD) Protection:

    • Handle the device with ESD protection measures to prevent damage from static electricity.
    • Use grounded wrist straps and ESD-safe workstations.
  9. Testing and Troubleshooting:

    • Regularly test the device parameters to ensure it is operating within the specified limits.
    • If the device fails, check for overvoltage, overcurrent, or overheating conditions.
(For reference only)

View more about IR4428S on main site