Details
BUY IR4428S https://www.utsource.net/itm/p/12606833.html
| Parameter | Symbol | Test Conditions | Min | Typical | Max | Unit |
|---|---|---|---|---|---|---|
| Drain-Source Voltage | VDS | - | - | - | 60 | V |
| Gate-Source Voltage | VGS | - | -15 | - | 15 | V |
| Continuous Drain Current | ID | VDS = 5V, TA = 25掳C | - | 12 | - | A |
| Pulse Drain Current | ID(p) | VDS = 5V, TC = 25掳C, tp = 10渭s | - | 36 | - | A |
| Total Power Dissipation | PTOT | TC = 25掳C | - | - | 100 | W |
| Junction Temperature | TJ | - | -55 | - | 150 | 掳C |
| Storage Temperature | TSTG | - | -55 | - | 150 | 掳C |
| Thermal Resistance, Junction to Case | R胃JC | - | - | 0.5 | - | 掳C/W |
Instructions for Use:
Mounting and Handling:
- Ensure that the device is mounted on a heatsink if operating at high power levels.
- Handle the device with care to avoid damage to the leads or the body.
Gate Drive:
- Apply a gate-source voltage (VGS) between 10V and 15V for optimal performance.
- Avoid applying voltages outside the specified range to prevent damage.
Drain-Source Voltage:
- Ensure that the drain-source voltage (VDS) does not exceed 60V to avoid breakdown.
Continuous and Pulse Current:
- The continuous drain current (ID) should not exceed 12A at room temperature.
- For pulse applications, the peak current (ID(p)) can be up to 36A for short durations (10渭s).
Power Dissipation:
- The total power dissipation (PTOT) should not exceed 100W to prevent overheating.
- Use appropriate cooling methods such as heatsinks or forced air cooling to manage heat.
Temperature Considerations:
- The junction temperature (TJ) should be kept below 150掳C.
- Store the device in an environment where the temperature ranges from -55掳C to 150掳C.
Thermal Management:
- Monitor the thermal resistance (R胃JC) to ensure effective heat transfer from the junction to the case.
- Use thermal paste or other thermal management materials to enhance heat dissipation.
Electrostatic Discharge (ESD) Protection:
- Handle the device with ESD protection measures to prevent damage from static electricity.
- Use grounded wrist straps and ESD-safe workstations.
Testing and Troubleshooting:
- Regularly test the device parameters to ensure it is operating within the specified limits.
- If the device fails, check for overvoltage, overcurrent, or overheating conditions.
View more about IR4428S on main site