BTA24

BTA24


Specifications
SKU
12606903
Details

BUY BTA24 https://www.utsource.net/itm/p/12606903.html

Parameter Symbol Min Typ Max Unit Description
Rated RMS Current IRM - 16 - A Maximum continuous RMS current
Non-Repetitive Peak On-State Current ITSM - 100 - A Maximum non-repetitive peak on-state current
Repetitive Peak On-State Current (10 ms) ITM - 50 - A Maximum repetitive peak on-state current for 10 ms
On-State Voltage Drop at 16A VTM - 1.3 - V Voltage drop when the triac is on and conducting 16A
Holding Current IH 10 30 50 mA Minimum current required to maintain on-state
Gate Trigger Current IGT 5 50 100 mA Current required to trigger the triac
Gate Trigger Voltage VGT 0.8 1.5 2.0 V Voltage required to trigger the triac
Maximum Off-State Voltage VDRM - 400 - V Maximum voltage the triac can block when off
Junction Temperature TJ -40 - 125 掳C Operating temperature range of the triac
Storage Temperature TSTG -40 - 125 掳C Temperature range for storage
Power Dissipation PD - 100 - W Maximum power dissipation

Instructions for Use:

  1. Mounting:

    • Ensure the BTA24 is mounted on a heatsink if it will be operating at or near its maximum current ratings.
    • Use thermal compound between the triac and the heatsink to improve heat transfer.
  2. Triggering:

    • The gate trigger current (IGT) must be sufficient to turn the triac on. Ensure that the gate current is within the specified range (5-100 mA).
    • The gate trigger voltage (VGT) should be within 0.8 to 2.0 V.
  3. Current Handling:

    • Do not exceed the rated RMS current (16 A) for continuous operation.
    • For short-term peak currents, ensure they do not exceed the non-repetitive peak on-state current (100 A) or the repetitive peak on-state current (50 A for 10 ms).
  4. Voltage Blocking:

    • The triac can block up to 400 V in the off-state. Ensure the supply voltage does not exceed this value.
  5. Temperature Management:

    • Operate the triac within the junction temperature range (-40掳C to 125掳C).
    • Store the triac within the storage temperature range (-40掳C to 125掳C).
  6. Holding Current:

    • Ensure the load current remains above the holding current (10-50 mA) to keep the triac in the on-state.
  7. Surge Protection:

    • Consider using a snubber circuit (RC network) to protect against voltage transients and surges.
  8. Testing:

    • Before installing the triac in a final application, test it under controlled conditions to ensure proper operation.

By following these guidelines, you can ensure reliable and safe operation of the BTA24 triac.

(For reference only)