Details
BUY BTA24-800 https://www.utsource.net/itm/p/12606904.html
| Parameter | Symbol | Conditions | Min | Typ | Max | Unit |
|---|---|---|---|---|---|---|
| Repetitive Peak Off-State Voltage | VDRM | Tj = 25°C | 800 | V | ||
| Repetitive Peak Reverse Voltage | VRRM | Tj = 25°C | 800 | V | ||
| On-State Current (rms) | IT(RMS) | Tj ≤ 100°C, 1 cycle max | 24 | A | ||
| Non-Repetitive Peak On-State Current | I TTSM | Tj = 25°C, t = 10 ms | 150 | A | ||
| Holding Current | IH | 30 | mA | |||
| Gate Trigger Current | IG(T) | Tj = 25°C | 10 | 50 | mA | |
| Maximum Junction Temperature | Tj(max) | 125 | °C |
Instructions for BTA24-800
Mounting and Handling:
- Ensure the device is mounted on a heatsink if continuous operation at high currents or in high ambient temperatures is expected.
- Handle with care to avoid damage to the leads and body.
Operating Voltage:
- Do not exceed the repetitive peak off-state voltage (VDRM) and repetitive peak reverse voltage (VRRM) ratings to prevent breakdown.
Current Ratings:
- The on-state current (IT(RMS)) should not be exceeded for more than one cycle of the AC waveform to avoid overheating.
- For non-repetitive conditions, ensure the peak on-state current (I TTSM) does not exceed the specified limit within the given time frame.
Gate Control:
- Apply sufficient gate trigger current (IG(T)) to ensure reliable turn-on. The typical value is around 10 mA, but it can go up to 50 mA under certain conditions.
Temperature Considerations:
- Keep the junction temperature (Tj) below the maximum allowed value (125°C) to maintain long-term reliability.
Testing and Verification:
- Verify that the holding current (IH) is sufficient to keep the device in the on-state once triggered.
- Conduct thorough testing under actual operating conditions to ensure all parameters are within safe limits.
Storage and Transportation:
- Store in a dry environment and protect from electrostatic discharge (ESD) during transportation and handling.
View more about BTA24-800 on main site