COM81C17

COM81C17


Specifications
Details

BUY COM81C17 https://www.utsource.net/itm/p/12606932.html

Parameter Description Value Unit
Supply Voltage Operating voltage range 4.5 to 5.5 V
Output Current Maximum output current per channel 25 mA
Operating Temp Temperature range for operation -40 to +85 掳C
Storage Temp Temperature range for storage -65 to +150 掳C
Input Voltage Maximum input voltage 5.5 V
Channel Number of channels 8

Instructions for COM81C17

  1. Power Supply Connection:

    • Connect the power supply pins (VCC and GND) to a stable 5V DC source within the specified operating voltage range.
  2. Input Signal Handling:

    • Ensure that the input signals do not exceed the maximum input voltage of 5.5V to prevent damage to the device.
  3. Output Configuration:

    • The COM81C17 can drive up to 25mA per channel. Make sure the load connected to each output does not exceed this limit.
  4. Temperature Considerations:

    • Operate the device within the temperature range of -40掳C to +85掳C. For storage, ensure temperatures remain between -65掳C and +150掳C.
  5. Channel Usage:

    • The device supports 8 independent channels. Configure each channel as required by your application.
  6. Installation and Handling:

    • Handle with care to avoid electrostatic discharge (ESD) damage. Follow proper anti-static procedures during installation.
  7. Testing:

    • After installation, test each channel to ensure proper functionality before deploying in critical applications.
(For reference only)

View more about COM81C17 on main site