Details
BUY COM81C17 https://www.utsource.net/itm/p/12606932.html
| Parameter | Description | Value | Unit |
|---|---|---|---|
| Supply Voltage | Operating voltage range | 4.5 to 5.5 | V |
| Output Current | Maximum output current per channel | 25 | mA |
| Operating Temp | Temperature range for operation | -40 to +85 | 掳C |
| Storage Temp | Temperature range for storage | -65 to +150 | 掳C |
| Input Voltage | Maximum input voltage | 5.5 | V |
| Channel | Number of channels | 8 |
Instructions for COM81C17
Power Supply Connection:
- Connect the power supply pins (VCC and GND) to a stable 5V DC source within the specified operating voltage range.
Input Signal Handling:
- Ensure that the input signals do not exceed the maximum input voltage of 5.5V to prevent damage to the device.
Output Configuration:
- The COM81C17 can drive up to 25mA per channel. Make sure the load connected to each output does not exceed this limit.
Temperature Considerations:
- Operate the device within the temperature range of -40掳C to +85掳C. For storage, ensure temperatures remain between -65掳C and +150掳C.
Channel Usage:
- The device supports 8 independent channels. Configure each channel as required by your application.
Installation and Handling:
- Handle with care to avoid electrostatic discharge (ESD) damage. Follow proper anti-static procedures during installation.
Testing:
- After installation, test each channel to ensure proper functionality before deploying in critical applications.
View more about COM81C17 on main site