| Parameter | Symbol | Min | Typ | Max | Unit | Notes |
|---|---|---|---|---|---|---|
| Continuous Drain Current | ID | - | 5.5 | 7.5 | A | @ Tc = 25掳C, VGS = 10V |
| Pulsed Drain Current (t = 10ms) | IDM | - | 9.0 | 12.0 | A | @ Tc = 25掳C, VGS = 10V |
| Gate-Source Voltage | VGS | -18 | - | 18 | V | Absolute Maximum Rating |
| Drain-Source Voltage | VDS | - | 60 | 60 | V | Absolute Maximum Rating |
| Power Dissipation | PD | - | - | 3.4 | W | @ Tc = 25掳C, 胃JA = 62掳C/W |
| Junction Temperature | TJ | -55 | - | 150 | 掳C | Operating Range |
| Storage Temperature | TSTG | -55 | - | 150 | 掳C | Storage Range |
| Thermal Resistance, Junction to Ambient | R胃JA | - | 62 | - | 掳C/W | Typical Value |
| On-State Resistance | RDS(on) | - | 0.035 | 0.045 | 惟 | @ VGS = 10V, ID = 5A |
| Gate Charge | Qg | - | 40 | 50 | nC | @ VDS = 30V, ID = 5A |
| Input Capacitance | Ciss | - | 1400 | 1800 | pF | @ VDS = 30V |
| Output Capacitance | Coss | - | 400 | 500 | pF | @ VDS = 30V |
| Reverse Transfer Capacitance | Crss | - | 200 | 250 | pF | @ VDS = 30V |
| Turn-On Delay Time | td(on) | - | 12 | 18 | ns | @ VGS = 10V, ID = 5A, VDS = 30V |
| Rise Time | tr | - | 25 | 35 | ns | @ VGS = 10V, ID = 5A, VDS = 30V |
| Turn-Off Delay Time | td(off) | - | 15 | 22 | ns | @ VGS = 10V, ID = 5A, VDS = 30V |
| Fall Time | tf | - | 20 | 28 | ns | @ VGS = 10V, ID = 5A, VDS = 30V |
Instructions for Use:
Power Supply and Grounding:
- Ensure that the power supply voltage is within the specified range (VDS).
- Properly ground the source terminal to avoid potential damage.
Heat Management:
- The device has a maximum power dissipation (PD) of 3.4W at 25掳C ambient temperature.
- Use appropriate heat sinks or cooling methods to manage the junction temperature (TJ) within the operating range (-55掳C to 150掳C).
Gate Drive:
- Apply a gate-source voltage (VGS) within the specified range (-18V to 18V).
- For optimal performance, use a gate drive voltage of 10V to minimize on-state resistance (RDS(on)).
Current Handling:
- Do not exceed the continuous drain current (ID) of 7.5A or the pulsed drain current (IDM) of 12A for short durations (10ms).
- Ensure that the load current does not exceed these limits to prevent damage.
Capacitance and Timing:
- Consider the input capacitance (Ciss), output capacitance (Coss), and reverse transfer capacitance (Crss) when designing the circuit to avoid oscillations or instability.
- Use the turn-on delay time (td(on)), rise time (tr), turn-off delay time (td(off)), and fall time (tf) to optimize switching performance.
Storage and Handling:
- Store the device in a dry environment with temperatures between -55掳C and 150掳C.
- Handle the device with care to avoid static discharge and physical damage.
Safety Precautions:
- Always follow proper handling and installation procedures to ensure the safety of both the device and personnel.
- Refer to the datasheet for additional safety and application notes.