Details
BUY JT015N065FED https://www.utsource.net/itm/p/12607035.html
| Parameter | Symbol | Min | Typ | Max | Unit | Description |
|---|---|---|---|---|---|---|
| Drain-Source Voltage | VDS | - | 650 | - | V | Maximum voltage between drain and source with gate open |
| Gate-Source Voltage | VGS | -20 | - | 20 | V | Maximum voltage between gate and source |
| Continuous Drain Current | ID | - | 15 | - | A | Continuous current flowing from drain to source at TC = 25°C |
| Pulse Drain Current | IDpeak | - | 45 | - | A | Peak current flowing from drain to source (tpulse ≤ 10 μs) |
| Power Dissipation | PTOT | - | 180 | - | W | Total power dissipation at TC = 25°C |
| Junction Temperature | TJ | - | - | 175 | °C | Maximum junction temperature |
| Storage Temperature | TSTG | -55 | - | 150 | °C | Operating temperature range for storage and handling |
| Thermal Resistance | RθJC | - | 0.7 | - | °C/W | Junction-to-case thermal resistance |
Instructions:
Handling and Storage:
- Store the device in a dry, cool place away from direct sunlight.
- Handle the device with care to avoid mechanical damage and static discharge.
Mounting:
- Ensure proper heat sinking to maintain the junction temperature within the specified limits.
- Use appropriate mounting hardware to secure the device firmly to the heatsink.
Electrical Connections:
- Connect the drain, source, and gate terminals correctly to avoid damage.
- Use suitable wire gauges to handle the current ratings.
Operation:
- Do not exceed the maximum ratings for voltage, current, and power dissipation.
- Monitor the junction temperature to ensure it does not exceed 175°C.
- For pulse operation, ensure that the pulse width and frequency do not exceed the specified limits.
Testing:
- Perform initial testing at room temperature to verify correct operation.
- Gradually increase the load and monitor performance parameters to ensure stability.
Safety:
- Always use protective equipment when handling high-voltage and high-current circuits.
- Follow all local regulations and guidelines for electrical safety.
Troubleshooting:
- If the device fails to operate correctly, check for proper connections and power supply.
- Measure the drain-source voltage and current to identify any issues.
- Consult the datasheet or contact the manufacturer for further assistance.
View more about JT015N065FED on main site