Details
BUY SIHG73N60E https://www.utsource.net/itm/p/12607061.html
| Parameter | Symbol | Min | Typical | Max | Unit | Conditions |
|---|---|---|---|---|---|---|
| Drain-Source On-State Resistance | RDS(on) | - | 180 | - | m惟 | VGS = 10V, ID = 25A, Tj = 25掳C |
| Drain-Source Breakdown Voltage | VDS(BR) | - | 600 | - | V | ID = 250渭A, Tj = 25掳C |
| Gate-Source Threshold Voltage | VGS(th) | 2.0 | 4.0 | 6.0 | V | ID = 250渭A, Tj = 25掳C |
| Input Capacitance | Ciss | - | 1900 | - | pF | VDS = 400V, f = 1MHz, Tj = 25掳C |
| Output Capacitance | Coss | - | 250 | - | pF | VDS = 400V, f = 1MHz, Tj = 25掳C |
| Reverse Transfer Capacitance | Crss | - | 280 | - | pF | VDS = 400V, f = 1MHz, Tj = 25掳C |
| Continuous Drain Current | ID | - | 25 | - | A | VDS = 400V, TC = 25掳C |
| Pulse Drain Current | ID(pk) | - | 75 | - | A | VDS = 400V, tp = 10ms, Tj = 25掳C |
| Total Power Dissipation | PTOT | - | 200 | - | W | TC = 25掳C |
| Junction Temperature | Tj | - | - | 150 | 掳C | - |
| Storage Temperature Range | Tstg | -55 | - | 150 | 掳C | - |
Instructions for Use:
Handling and Storage:
- Store the device in a dry, cool place.
- Handle with care to avoid static damage. Use ESD protection when handling.
Mounting:
- Ensure proper heat sinking to manage thermal resistance.
- Use appropriate mounting torque for screws to ensure good thermal contact.
Biasing:
- Apply gate-source voltage (VGS) within the specified range to avoid damage.
- Ensure VGS is not less than the threshold voltage (VGS(th)) to turn on the device.
Operation:
- Do not exceed the maximum drain-source voltage (VDS(BR)) to prevent breakdown.
- Keep the junction temperature (Tj) below the maximum rating to avoid thermal damage.
- Operate within the continuous drain current (ID) limits to ensure reliable performance.
Testing:
- Use a suitable test setup to measure parameters accurately.
- Ensure all connections are secure and insulated to prevent short circuits.
Safety:
- Follow all safety guidelines and regulations when working with high voltages and currents.
- Use appropriate personal protective equipment (PPE) as necessary.
For detailed specifications and further information, refer to the datasheet provided by the manufacturer.
(For reference only)View more about SIHG73N60E on main site