Parameter Symbol Min Typ Max Unit
Supply Voltage Vcc 4.5 5.0 5.5 V
Standby Current Icc(s) - 10 - 渭A
Active Current Icc(a) - 30 - mA
Output High Voltage VOH 2.4 - Vcc-0.5 V
Output Low Voltage VOL 0 - 0.5 V
Input High Voltage VIH 2.0 - Vcc-0.8 V
Input Low Voltage VIL 0 - 0.8 V
Data Access Time ta 0 70 100 ns
Address Access Time taa 0 70 100 ns
Write Cycle Time twc 0 150 200 ns
Chip Enable Setup Time tces 0 20 40 ns
Chip Enable Hold Time tceh 0 20 40 ns
Output Enable Setup Time toes 0 20 40 ns
Output Enable Hold Time toe 0 20 40 ns
Write Enable Setup Time twes 0 20 40 ns
Write Enable Hold Time tweh 0 20 40 ns
Power-up Time tpw 0 200 - ns
Power-down Time tpd 0 200 - ns

Instructions for IDT71256SA12TP

  1. Power Supply:

    • Ensure the supply voltage (Vcc) is within the range of 4.5V to 5.5V.
    • Use a stable power source to avoid fluctuations that could affect performance.
  2. Current Considerations:

    • The standby current (Icc(s)) is typically around 10渭A.
    • The active current (Icc(a)) can reach up to 30mA during operation.
  3. Voltage Levels:

    • Output high voltage (VOH) should be at least 2.4V and can go up to Vcc - 0.5V.
    • Output low voltage (VOL) should not exceed 0.5V.
    • Input high voltage (VIH) should be at least 2.0V and can go up to Vcc - 0.8V.
    • Input low voltage (VIL) should not exceed 0.8V.
  4. Timing Parameters:

    • Data access time (ta) and address access time (taa) are both typically 70ns with a maximum of 100ns.
    • Write cycle time (twc) is typically 150ns with a maximum of 200ns.
    • Chip enable setup time (tces) and hold time (tceh) are both typically 20ns with a maximum of 40ns.
    • Output enable setup time (toes) and hold time (toe) are both typically 20ns with a maximum of 40ns.
    • Write enable setup time (twes) and hold time (tweh) are both typically 20ns with a maximum of 40ns.
    • Power-up time (tpw) and power-down time (tpd) are both typically 200ns.
  5. Handling and Storage:

    • Handle the device with care to avoid static discharge.
    • Store in a dry, cool place to prevent moisture damage.
  6. Operating Conditions:

    • Ensure the operating temperature is within the specified range for reliable performance.
    • Avoid exposing the device to extreme temperatures or humidity.
  7. Testing and Verification:

    • Perform initial testing under controlled conditions to verify all parameters meet the specifications.
    • Regularly check the device for any signs of wear or malfunction.

By following these instructions, you can ensure optimal performance and longevity of the IDT71256SA12TP.

(For reference only)

View more about IDT71256SA12TP on main site