Parameter Symbol Min Typ Max Unit Notes
Input Voltage V_IN 4.5 - 28 V
Output Voltage V_OUT 5.0 - 5.0 V Fixed
Output Current I_OUT - 300 500 mA
Quiescent Current I_Q - 1.5 2.5 mA
Dropout Voltage V_DROPOUT - 0.5 1.0 V @ I_OUT = 500mA
Load Regulation - - 0.5 1.0 % 0 to 500mA
Line Regulation - - 0.1 0.2 %/V 4.5 to 28V
Ripple Rejection - 60 70 80 dB 1kHz
Operating Temperature T_OP -40 - 85 掳C
Storage Temperature T_STG -65 - 150 掳C

Instructions for Use:

  1. Input Connection:

    • Connect the input voltage (V_IN) to the Vin pin. Ensure the input voltage is within the specified range (4.5V to 28V).
  2. Output Connection:

    • Connect the output voltage (V_OUT) to the Vout pin. The output is fixed at 5.0V.
  3. Ground Connection:

    • Connect the ground (GND) to both the input and output ground pins.
  4. Capacitors:

    • Place a 10渭F electrolytic capacitor between the input and ground close to the input pin to filter out noise.
    • Place a 10渭F electrolytic capacitor between the output and ground close to the output pin to stabilize the output voltage.
  5. Thermal Considerations:

    • Ensure adequate heat dissipation if operating at high output currents or in high ambient temperatures. The device may require a heatsink if the power dissipation exceeds the thermal limits.
  6. Load Regulation:

    • The load regulation is typically 0.5% to 1.0%. Ensure that the load current does not exceed 500mA to maintain optimal performance.
  7. Line Regulation:

    • The line regulation is typically 0.1% to 0.2% per volt. This ensures that the output voltage remains stable over the input voltage range.
  8. Ripple Rejection:

    • The ripple rejection is typically 60dB to 80dB at 1kHz, which helps in filtering out input voltage fluctuations.
  9. Operating and Storage Temperature:

    • The device can operate within a temperature range of -40掳C to 85掳C and can be stored between -65掳C and 150掳C.
  10. Handling Precautions:

    • Handle the device with care to avoid static discharge, which can damage the internal components.
    • Follow standard ESD (Electrostatic Discharge) precautions during handling and assembly.