Details
BUY EE-SX3081 https://www.utsource.net/itm/p/12607127.html
| Parameter | Symbol | Conditions | Min | Typ | Max | Unit |
|---|---|---|---|---|---|---|
| Operating Voltage | VCC | Continuous operation | 4.5 | - | 24 | V |
| Operating Current | ICC | Continuous operation | - | 10 | - | mA |
| Output Type | - | NPN Open Collector | - | - | ||
| Maximum Load Current | IOL | VCE = 30V, TA = 25掳C | - | - | 50 | mA |
| Maximum Collector-Emitter Voltage | VCE | Continuous operation | - | - | 30 | V |
| Maximum Emitter-Base Voltage | VEB | Continuous operation | - | - | 5 | V |
| Maximum Junction Temperature | TJ | Continuous operation | - | - | 125 | 掳C |
| Storage Temperature Range | TSTG | Non-operating | -40 | - | 85 | 掳C |
| Response Time (ON) | tr | VCC = 24V, RL = 1k惟 | - | 0.5 | - | ms |
| Response Time (OFF) | tf | VCC = 24V, RL = 1k惟 | - | 0.5 | - | ms |
Instructions for Use:
Power Supply:
- Ensure the operating voltage is within the range of 4.5V to 24V.
- The typical operating current is 10mA.
Output Configuration:
- The EE-SX3081 has an NPN open collector output.
- Connect an external pull-up resistor between the output and the supply voltage to ensure proper operation.
Load Current:
- Do not exceed the maximum load current of 50mA to avoid damaging the device.
- Ensure the load resistance is appropriate for the desired current.
Voltage Ratings:
- The maximum collector-emitter voltage (VCE) should not exceed 30V.
- The maximum emitter-base voltage (VEB) should not exceed 5V.
Temperature Considerations:
- The maximum junction temperature (TJ) should not exceed 125掳C.
- Store the device in an environment where the temperature ranges from -40掳C to 85掳C.
Response Time:
- The typical response time for both ON and OFF states is 0.5ms when using a 24V supply and a 1k惟 load resistor.
Handling:
- Handle the device with care to avoid static damage.
- Follow standard ESD (Electrostatic Discharge) precautions during handling and installation.
Mounting:
- Ensure proper mounting to maintain thermal performance and mechanical stability.
- Use appropriate fasteners and follow the recommended torque values if applicable.
Testing:
- Test the device under the specified operating conditions to ensure it meets the required performance specifications.
Compliance:
- Ensure the device complies with all relevant safety and regulatory standards for your application.
View more about EE-SX3081 on main site