STP25NM60ND

STP25NM60ND


Specifications
SKU
12607172
Details

BUY STP25NM60ND https://www.utsource.net/itm/p/12607172.html

Parameter Symbol Min Typical Max Unit Conditions
Drain-Source Voltage VDS -60 - - V
Gate-Source Voltage VGS -10 - +20 V
Continuous Drain Current ID - 25 - A TC = 25掳C
Pulse Drain Current ID(p) - 85 - A TC = 25掳C, tp = 10 ms, IG = 10 A
Power Dissipation PTOT - - 140 W TC = 25掳C
Junction Temperature TJ - - 175 掳C
Storage Temperature TSTG -55 - 150 掳C
Total Gate Charge QG - 19 - nC VGS = 15 V
Input Capacitance Ciss - 1430 - pF VDS = 25 V
Output Capacitance Coss - 130 - pF VDS = 25 V
Reverse Transfer Capacitance Crss - 350 - pF VDS = 25 V
On-State Resistance RDS(on) - 0.12 - VGS = 10 V, ID = 25 A
Threshold Voltage VGS(th) 2.0 2.5 3.0 V ID = 250 渭A

Instructions for Use:

  1. Handling Precautions:

    • Handle with care to avoid static damage.
    • Ensure proper heat sinking to manage power dissipation.
  2. Mounting:

    • Use appropriate mounting hardware to secure the device.
    • Ensure good thermal contact between the device and the heatsink.
  3. Biasing:

    • Apply gate-source voltage (VGS) within the specified range to control the drain current (ID).
    • Ensure that the gate drive circuitry is capable of providing sufficient current to charge and discharge the gate capacitance quickly.
  4. Thermal Management:

    • Monitor the junction temperature (TJ) to ensure it does not exceed the maximum rating.
    • Use thermal paste or thermal interface materials to enhance heat transfer.
  5. Electrical Stress:

    • Do not exceed the maximum ratings for drain-source voltage (VDS), gate-source voltage (VGS), and continuous drain current (ID).
    • Ensure that the device is protected from overvoltage and overcurrent conditions.
  6. Storage:

    • Store in a dry, cool environment to prevent moisture damage.
    • Follow recommended storage conditions to maintain device reliability.
  7. Testing:

    • Use appropriate test equipment to verify the device parameters before installation.
    • Perform functional tests under typical operating conditions to ensure proper performance.
(For reference only)

View more about STP25NM60ND on main site