S10VB60 07

S10VB60 07


Specifications
SKU
12607176
Details

BUY S10VB60 07 https://www.utsource.net/itm/p/12607176.html

Parameter Symbol Min Typ Max Unit Notes
Input Voltage V_IN 4.5 - 60 V
Output Voltage V_OUT - 5 - V Fixed
Output Current I_OUT - 1 1.2 A
Efficiency - 85 - %
Switching Frequency f_SW - 500 - kHz
Quiescent Current I_Q - 20 - 渭A
Dropout Voltage V_DROPOUT - 0.7 - V
Operating Temperature T_OP -40 - 85 掳C
Storage Temperature T_STG -55 - 125 掳C

Instructions for Use:

  1. Input Voltage (V_IN):

    • Ensure the input voltage is within the range of 4.5V to 60V.
    • Do not exceed the maximum input voltage to avoid damage to the device.
  2. Output Voltage (V_OUT):

    • The output voltage is fixed at 5V. No external components are required to set this voltage.
  3. Output Current (I_OUT):

    • The device can provide up to 1.2A of output current, with a typical output current of 1A.
    • Ensure the load does not exceed the maximum output current to prevent overheating or damage.
  4. Efficiency (畏):

    • The efficiency is typically around 85%. This value can vary depending on the input voltage and load conditions.
  5. Switching Frequency (f_SW):

    • The switching frequency is fixed at 500kHz. This helps in minimizing the size of external components like inductors and capacitors.
  6. Quiescent Current (I_Q):

    • The quiescent current is typically 20渭A. This low current consumption makes the device suitable for battery-powered applications.
  7. Dropout Voltage (V_DROPOUT):

    • The dropout voltage is 0.7V. This means the input voltage must be at least 0.7V higher than the output voltage for the regulator to function properly.
  8. Operating Temperature (T_OP):

    • The device can operate within a temperature range of -40掳C to 85掳C. Ensure the ambient temperature stays within this range to maintain reliable operation.
  9. Storage Temperature (T_STG):

    • The device can be stored within a temperature range of -55掳C to 125掳C. However, ensure it is brought back to operating temperature before use.
  10. Mounting and Handling:

    • Handle the device with care to avoid static discharge and physical damage.
    • Follow proper soldering techniques to ensure a secure and reliable connection.
  11. Capacitor Selection:

    • Use high-quality ceramic capacitors for input and output filtering to ensure stable operation.
    • Typical values for input and output capacitors are 10渭F and 10渭F, respectively.
  12. Inductor Selection:

    • Choose an inductor with a saturation current rating higher than the maximum output current.
    • A typical inductor value is 10渭H.
  13. PCB Layout:

    • Keep the input and output capacitors close to the device to minimize noise and improve stability.
    • Use wide traces for power connections to reduce resistance and heat generation.

By following these instructions, you can ensure optimal performance and reliability of the S10VB60 07.