Parameter Symbol Conditions Min Typ Max Unit
Supply Voltage Vcc Operating 4.5 5.0 5.5 V
Output Current Iout Continuous - 250 - mA
Standby Current Isb Vcc = 5V, no load - 1.5 - mA
Output Voltage Vout No load 4.75 5.0 5.25 V
Line Regulation ΔVout/ΔVin Vcc = 4.5V to 5.5V - 0.01 - %
Load Regulation ΔVout/ΔIout Iout = 0mA to 250mA - 0.01 - %
Dropout Voltage Vdo Iout = 250mA - 0.5 - V
Ripple Rejection RR 10Hz to 100kHz - 60 - dB
Operating Temperature Topr - -40 85 - °C
Storage Temperature Tstg - -65 150 - °C

Instructions for Use:

  1. Power Supply Connection:

    • Connect the positive terminal of the power supply to the Vcc pin.
    • Connect the ground (GND) of the power supply to the GND pin.
  2. Output Connection:

    • Connect the load to the Vout pin.
    • Ensure the load does not exceed the maximum output current (250mA).
  3. Capacitors:

    • Place a 10μF tantalum capacitor between Vcc and GND close to the regulator to ensure stability.
    • Place a 10μF tantalum capacitor between Vout and GND to filter the output and reduce ripple.
  4. Thermal Considerations:

    • The device should be mounted on a heatsink if it is expected to operate at high output currents or in high ambient temperatures.
    • Ensure the operating temperature remains within the specified range (-40°C to 85°C).
  5. PCB Layout:

    • Keep the traces from Vcc to the regulator and from the regulator to Vout as short as possible to minimize inductance and improve stability.
    • Use wide traces for the ground plane to reduce resistance and improve heat dissipation.
  6. Testing:

    • Before connecting the load, test the output voltage with a multimeter to ensure it is within the specified range (4.75V to 5.25V).
    • Monitor the temperature of the regulator during operation to ensure it does not overheat.
  7. Storage:

    • Store the device in a dry, cool place away from direct sunlight and sources of heat.
    • Handle the device with care to avoid damage to the pins and the internal components.