| Parameter | Symbol | Conditions | Min | Typ | Max | Unit |
|---|---|---|---|---|---|---|
| Input Voltage | VIN | 3.0 | 5.5 | V | ||
| Output Voltage | VOUT | 3.0 | 3.3 | 3.6 | V | |
| Isolation Voltage | VISOL | Rated | 2500 | Vrms | ||
| Propagation Delay Time | tPD | VCC = 5V, TA = 25掳C | 10 | 18 | ns | |
| Pulse Width Distortion | tPWD | VCC = 5V, TA = 25掳C | -4 | 4 | ns | |
| Common Mode Transient Immunity | CMR | VCC = 5V, TA = 25掳C | 25 | kV/渭s | ||
| Operating Temperature | Toper | Storage | -40 | 85 | 掳C | |
| Storage Temperature | Tstg | -40 | 85 | 掳C |
Instructions for ACPL-H312-000E
Power Supply Requirements:
- Ensure the input voltage (VIN) is within the range of 3.0V to 5.5V.
- The output voltage (VOUT) should be maintained between 3.0V and 3.6V.
Isolation Considerations:
- Maintain isolation voltage (VISOL) up to 2500 Vrms as rated.
Timing Parameters:
- Monitor propagation delay time (tPD) which typically ranges from 10ns to 18ns under standard conditions (VCC = 5V, TA = 25掳C).
- Keep pulse width distortion (tPWD) within 卤4ns for optimal performance.
Electromagnetic Compatibility:
- Ensure common mode transient immunity (CMR) is at least 25 kV/渭s to handle fast transients effectively.
Temperature Management:
- Operate within a temperature range of -40掳C to 85掳C for both operating and storage conditions.
Handling Precautions:
- Handle with care to avoid damage due to electrostatic discharge (ESD). Use appropriate ESD protection measures.
- Follow manufacturer guidelines for mounting and soldering to ensure reliable operation.