AT25160A

AT25160A


Specifications
SKU
12607270
Details

BUY AT25160A https://www.utsource.net/itm/p/12607270.html

Parameter Description Min Typ Max Unit
VCC Supply Voltage 1.7 - 3.6 V
ICC Supply Current (Active) - 1.0 - mA
ICC (Standby) Supply Current (Standby) - 1.0 - 渭A
fSCL Clock Frequency 100 - 400 kHz
tRHOLD Address Hold Time 0 - 10 ns
tSU Address Setup Time 0 - 25 ns
tAA Access Time 0 - 100 渭s
tWR Write Cycle Time 0 - 5 ms
tHOLD Data Hold Time 0 - 10 ns
tLOW SCL Low Period 4.7 - 13 渭s
tHIGH SCL High Period 4.0 - 13 渭s
tSU;STA Start Condition Setup Time 4.0 - - 渭s
tHOLD;STA Start Condition Hold Time 4.0 - - 渭s
tSU;STO Stop Condition Setup Time 4.0 - - 渭s
tBH Bus Free Time Between STOP and START Conditions 4.7 - - 渭s
tR Rise Time 100 - 300 ns
tF Fall Time 100 - 300 ns

Instructions for Using AT25160A

  1. Power Supply:

    • Ensure the supply voltage (VCC) is within the range of 1.7V to 3.6V.
    • The supply current (ICC) should not exceed 1.0mA in active mode and 1.0渭A in standby mode.
  2. Clock Frequency:

    • The clock frequency (fSCL) should be between 100kHz and 400kHz for proper operation.
  3. Timing Parameters:

    • Address Hold Time (tRHOLD): Ensure the address hold time is at least 0ns and no more than 10ns.
    • Address Setup Time (tSU): The address setup time should be at least 0ns and no more than 25ns.
    • Access Time (tAA): The access time should not exceed 100渭s.
    • Write Cycle Time (tWR): The write cycle time should not exceed 5ms.
    • Data Hold Time (tHOLD): The data hold time should be at least 0ns and no more than 10ns.
    • SCL Low Period (tLOW): The SCL low period should be between 4.7渭s and 13渭s.
    • SCL High Period (tHIGH): The SCL high period should be between 4.0渭s and 13渭s.
    • Start Condition Setup Time (tSU;STA): The start condition setup time should be at least 4.0渭s.
    • Start Condition Hold Time (tHOLD;STA): The start condition hold time should be at least 4.0渭s.
    • Stop Condition Setup Time (tSU;STO): The stop condition setup time should be at least 4.0渭s.
    • Bus Free Time Between STOP and START Conditions (tBH): The bus free time should be at least 4.7渭s.
    • Rise Time (tR): The rise time should be between 100ns and 300ns.
    • Fall Time (tF): The fall time should be between 100ns and 300ns.
  4. Communication Protocol:

    • Use the I2C protocol for communication.
    • Ensure proper pull-up resistors are used on the SDA and SCL lines to maintain signal integrity.
    • Follow the I2C protocol for start, stop, and data transfer conditions.
  5. Programming:

    • Refer to the device datasheet for specific commands and programming sequences.
    • Ensure that all write operations are followed by the appropriate write cycle time to avoid data corruption.
  6. Storage and Handling:

    • Store the device in a dry, cool environment to prevent damage.
    • Handle with care to avoid static discharge which can damage the device.

For detailed information, refer to the official AT25160A datasheet provided by the manufacturer.

(For reference only)

View more about AT25160A on main site