Details
BUY STC89C52RC-40-PLCC https://www.utsource.net/itm/p/12607282.html
| Parameter | Description | Value |
|---|---|---|
| Part Number | Device Identifier | STC89C52RC-40-PLCC |
| Package Type | Encapsulation | PLCC-44 |
| Operating Voltage (Vcc) | Supply Voltage Range | 4.0 V to 5.5 V |
| Operating Frequency | Maximum Clock Frequency | 40 MHz |
| Flash Memory | Program Memory Size | 8 KB |
| RAM | Data Memory Size | 256 bytes |
| EEPROM | Non-Volatile Data Storage | None |
| I/O Pins | Number of General Purpose I/O Pins | 32 |
| Timers/Counters | Number of Timers/Counters | 3 (T0, T1, T2) |
| Serial Communication Interfaces | UART, SPI, I2C | 1 UART, No SPI, No I2C |
| Interrupt Sources | Number of Interrupt Sources | 14 |
| Power Consumption | Typical Active Current at 12 MHz | 2.5 mA |
| Temperature Range | Operating Temperature | -40掳C to +85掳C |
| Programming Interface | In-System Programming (ISP) | Yes |
| Watchdog Timer | On-Chip Watchdog Timer | Yes |
| Low Voltage Detection | Brown-out Reset (BOR) | Yes |
| Power Management | Power-down Modes | Idle Mode, Power-down Mode |
| Package Dimensions | Physical Size | 11.7 x 11.7 mm |
Instructions for Use
Power Supply:
- Ensure the supply voltage (Vcc) is within the specified range of 4.0 V to 5.5 V.
- Connect the Vcc pin to the power supply and GND pin to ground.
Clock Configuration:
- The device supports a maximum clock frequency of 40 MHz. Use an external crystal or oscillator if required.
- For internal RC oscillator operation, configure the appropriate fuse bits.
Programming:
- Use an ISP programmer to program the flash memory.
- Ensure the programming voltage (Vpp) is applied correctly if using high-voltage programming.
I/O Configuration:
- Configure the I/O pins as inputs or outputs using the corresponding registers (P0, P1, P2, P3).
- Use pull-up resistors for open-drain configurations.
Timers/Counters:
- Initialize the timers/counters by setting the mode and prescaler values in the TCON and TMOD registers.
- Enable interrupts for timer overflow or capture events if needed.
Serial Communication:
- Configure the UART settings (baud rate, data bits, stop bits) in the SCON register.
- Use the TXD and RXD pins for serial communication.
Interrupts:
- Enable specific interrupt sources by setting the corresponding bits in the IE register.
- Write interrupt service routines (ISRs) to handle interrupt events.
Power Management:
- Use the idle mode to reduce power consumption while keeping the CPU running.
- Use the power-down mode to minimize power consumption when the device is not in use.
Watchdog Timer:
- Enable the watchdog timer to reset the microcontroller if it hangs.
- Clear the watchdog timer periodically to prevent an unintended reset.
Brown-out Reset:
- Enable the brown-out reset feature to automatically reset the microcontroller if the supply voltage drops below a certain threshold.
Handling:
- Handle the device with care to avoid static damage.
- Follow proper soldering techniques to ensure reliable connections.
For detailed information, refer to the datasheet and application notes provided by the manufacturer.
(For reference only)View more about STC89C52RC-40-PLCC on main site