Details
BUY IPP80N08S4-06 https://www.utsource.net/itm/p/12607285.html
| Parameter | Symbol | Test Conditions | Min | Typ | Max | Unit |
|---|---|---|---|---|---|---|
| Drain-Source Voltage | VDS | - | - | 800 | - | V |
| Gate-Source Voltage | VGS | - | - | 卤20 | - | V |
| Continuous Drain Current | ID | TC = 25掳C | - | - | 80 | A |
| ID | TC = 100掳C | - | - | 60 | A | |
| Pulse Drain Current | ID(peak) | tp = 10 渭s, IG = 5 A | - | - | 240 | A |
| Gate Charge | QG | VGS = 15 V, ID = 80 A | - | 70 | - | nC |
| Input Capacitance | Ciss | VDS = 400 V, f = 1 MHz | - | 2500 | - | pF |
| Output Capacitance | Coss | VDS = 400 V, f = 1 MHz | - | 300 | - | pF |
| Reverse Transfer Capacitance | Crss | VDS = 400 V, f = 1 MHz | - | 200 | - | pF |
| On-State Resistance | RDS(on) | VGS = 15 V, ID = 80 A | - | 0.06 | - | 惟 |
| Threshold Gate Voltage | VGS(th) | ID = 1 mA | - | 3.0 | 5.0 | V |
| Total Power Dissipation | PTOT | TC = 25掳C | - | - | 1200 | W |
| Junction Temperature | TJ | - | - | - | 175 | 掳C |
| Storage Temperature Range | TSTG | - | -65 | - | 150 | 掳C |
Instructions for Use:
Handling Precautions:
- The IPP80N08S4-06 is sensitive to electrostatic discharge (ESD). Use proper ESD protection when handling.
- Avoid exposing the device to temperatures outside its specified operating range.
Mounting:
- Ensure good thermal contact with the heatsink to manage heat dissipation effectively.
- Use recommended mounting torque for the screws to avoid damaging the device.
Gate Drive:
- Use a gate resistor to control the switching speed and reduce electromagnetic interference (EMI).
- Ensure the gate voltage does not exceed the maximum rating of 卤20 V.
Thermal Management:
- Monitor the junction temperature to prevent overheating. Use a heatsink or cooling system as necessary.
- Ensure adequate airflow around the device for optimal cooling.
Overcurrent Protection:
- Implement overcurrent protection to prevent damage from excessive current.
- Consider using a current-limiting circuit or fuse.
Storage:
- Store the device in a dry, cool place away from direct sunlight and sources of heat.
- Keep the device in its original packaging until ready for use to protect against ESD.
Testing:
- Use a high-voltage tester to verify insulation resistance before installation.
- Perform initial tests at low power levels to ensure proper operation before full-scale testing.