Details
BUY EXB842-0A https://www.utsource.net/itm/p/12607379.html
Below is the parameter table and instructions for the EXB842-0A:
Parameter Table
| Parameter | Symbol | Min | Typical | Max | Unit | Conditions |
|---|---|---|---|---|---|---|
| Supply Voltage | Vcc | 12 | - | 20 | V | - |
| Gate Drive Output Voltage | Vout | 10 | - | 15 | V | Vcc = 15V |
| Gate Drive Output Current | Iout | - | 1.5 | 2.0 | A | Vcc = 15V, t = 10渭s |
| Input High Level Voltage | VIH | 4.0 | - | 20 | V | - |
| Input Low Level Voltage | VIL | 0 | - | 1.0 | V | - |
| Input Leakage Current | IIH | - | 0.1 | 1.0 | 渭A | VIH = 15V |
| Input Capacitance | Cin | - | 10 | - | pF | f = 1 MHz, Vcc = 15V |
| Maximum Junction Temperature | Tj(max) | - | - | 150 | 掳C | - |
| Storage Temperature Range | Tstg | -40 | - | 125 | 掳C | - |
Instructions
Supply Voltage (Vcc):
- Ensure the supply voltage is within the range of 12V to 20V.
- The typical operating voltage is 15V.
Gate Drive Output:
- The gate drive output voltage (Vout) ranges from 10V to 15V when Vcc is 15V.
- The gate drive output current (Iout) can provide up to 2.0A for short durations (t = 10渭s).
Input Levels:
- For a high input level (VIH), the voltage should be at least 4.0V.
- For a low input level (VIL), the voltage should not exceed 1.0V.
Input Leakage Current (IIH):
- The input leakage current should not exceed 1.0渭A when the input is at a high level (VIH = 15V).
Input Capacitance (Cin):
- The input capacitance is typically 10pF at a frequency of 1 MHz and a supply voltage of 15V.
Temperature Considerations:
- The maximum junction temperature (Tj(max)) is 150掳C.
- The storage temperature range (Tstg) is from -40掳C to 125掳C.
Handling and Storage:
- Store the device in a dry environment to prevent moisture damage.
- Handle with care to avoid static discharge, which can damage the internal components.
Mounting and PCB Design:
- Ensure proper thermal management by providing adequate heat sinking if the device will operate at high temperatures or high power levels.
- Follow recommended PCB layout guidelines to minimize noise and ensure reliable operation.
Testing:
- Before final assembly, test the device under typical operating conditions to ensure it meets all specified parameters.
By following these instructions, you can ensure optimal performance and reliability of the EXB842-0A.
(For reference only)View more about EXB842-0A on main site