Details
BUY IPP057N08 https://www.utsource.net/itm/p/12607401.html
| Parameter | Symbol | Value | Unit | Conditions/Notes |
|---|---|---|---|---|
| Maximum Drain Voltage | VDSS | 80 | V | Max voltage between drain and source with gate shorted to source |
| Maximum Gate Voltage | VGS | 卤20 | V | Max voltage between gate and source |
| Continuous Drain Current | ID | 57 | A | At Tc = 25掳C, pulsed operation |
| Power Dissipation | PD | 143 | W | At Tc = 25掳C |
| Junction Temperature | TJ | -55 to 150 | 掳C | Operating temperature range |
| Storage Temperature | TSTG | -55 to 150 | 掳C | Storage temperature range |
| Total Gate Charge | Qg | 110 | nC | At VGS = 15V, IDS = 2A |
Instructions for IPP057N08:
Handling Precautions:
- Use caution when handling the device as it is sensitive to electrostatic discharge (ESD). Always use proper ESD protection measures.
Mounting Guidelines:
- Ensure proper thermal management by using appropriate heatsinks or cooling solutions, especially when operating near maximum power dissipation limits.
- Follow recommended PCB layout guidelines to ensure optimal performance and reliability.
Biasing and Drive Requirements:
- The gate drive voltage should not exceed the specified maximum gate voltage (卤20V) to avoid damaging the device.
- Ensure that the gate drive circuitry can supply sufficient current to charge and discharge the gate capacitance quickly, improving switching performance.
Operating Conditions:
- Operate within the specified junction temperature range (-55掳C to 150掳C) to maintain reliable operation.
- Keep the continuous drain current within the rated limit of 57A at a case temperature of 25掳C.
Testing and Verification:
- Verify all electrical connections and parameters before applying power to the device.
- Conduct regular testing and monitoring during operation to ensure compliance with specifications and prevent potential failures.
Storage and Transportation:
- Store in a dry, cool environment within the specified storage temperature range (-55掳C to 150掳C).
- Protect from physical damage during transportation.
View more about IPP057N08 on main site