IRG4BC20KD.

IRG4BC20KD.


Specifications
SKU
12607407
Details

BUY IRG4BC20KD. https://www.utsource.net/itm/p/12607407.html

Parameter Symbol Min Typ Max Unit Notes
Drain-Source Voltage VDS - 600 V
Gate-Source Voltage VGS -15 20 V
Continuous Drain Current ID - 18 - A @ TC = 25掳C
Pulse Drain Current ID(peak) - 36 - A @ TC = 25掳C, tp = 10 渭s
Power Dissipation Ptot - 220 W @ TC = 25掳C
Junction Temperature TJ - 175 掳C
Storage Temperature Tstg -55 150 掳C
Thermal Resistance (Junction to Case) R胃JC - 0.44 - 掳C/W
Input Capacitance Ciss - 1900 - pF @ VDS = 400V, f = 1 MHz
Output Capacitance Coss - 450 - pF @ VDS = 400V, f = 1 MHz
Reverse Transfer Capacitance Crss - 350 - pF @ VDS = 400V, f = 1 MHz
Turn-On Delay Time td(on) - 32 - ns @ ID = 10A, VGS = 10V, RG = 2惟
Rise Time tr - 35 - ns @ ID = 10A, VGS = 10V, RG = 2惟
Turn-Off Delay Time td(off) - 20 - ns @ ID = 10A, VGS = 10V, RG = 2惟
Fall Time tf - 30 - ns @ ID = 10A, VGS = 10V, RG = 2惟

Instructions:

  1. Mounting and Handling:

    • Ensure proper handling to avoid damage from electrostatic discharge (ESD).
    • Use appropriate thermal management techniques to maintain junction temperature within specified limits.
  2. Gate Drive:

    • Apply a gate-source voltage (VGS) between -15V and +20V.
    • Use a low impedance driver to minimize switching losses.
  3. Thermal Management:

    • Ensure adequate heat sinking to keep the junction temperature below 175掳C.
    • Calculate the power dissipation and thermal resistance to determine the required heat sink size.
  4. Storage and Operating Conditions:

    • Store the device in a dry, cool environment to prevent moisture damage.
    • Operate within the specified storage temperature range (-55掳C to 150掳C).
  5. Capacitance Considerations:

    • Account for input, output, and reverse transfer capacitances in circuit design to ensure stable operation and minimize switching losses.
  6. Switching Characteristics:

    • Use the turn-on and turn-off delay times, rise and fall times to optimize the switching performance and reduce electromagnetic interference (EMI).
  7. Safety Precautions:

    • Always follow safety guidelines when working with high voltages and currents.
    • Use protective equipment and follow proper grounding procedures.
(For reference only)