Details
BUY YAC516-E https://www.utsource.net/itm/p/12607423.html
| Parameter | Description | Value | Unit |
|---|---|---|---|
| Part Number | Product identifier | YAC516-E | - |
| Type | Device type | AC/DC Converter | - |
| Input Voltage | Range of input voltage it can handle | 85 to 264 | VAC |
| Output Voltage | Stable output voltage provided | 5 | VDC |
| Output Current | Maximum current it can provide | 3 | A |
| Efficiency | Efficiency rating | Up to 87% | % |
| Operating Temp. | Temperature range for operation | -40 to +85 | 掳C |
| Protection | Types of protection features | Overload, Short-circuit | - |
| Mounting | Method of installation | DIN Rail | - |
| Certifications | Safety and compliance standards met | CE, UL | - |
Instructions:
- Installation: Install the YAC516-E on a standard DIN rail in a well-ventilated area to ensure proper heat dissipation.
- Input Connection: Connect the input terminals to an AC power source within the specified voltage range (85 to 264 VAC).
- Output Connection: Connect your DC load to the output terminals ensuring the total current draw does not exceed 3A.
- Protection Settings: The device includes built-in overload and short-circuit protection which automatically resets once the fault condition is cleared.
- Operating Environment: Ensure the ambient temperature remains between -40掳C and +85掳C for optimal performance.
- Safety Compliance: Verify that the installation complies with local electrical codes and regulations. The YAC516-E meets CE and UL safety standards.
View more about YAC516-E on main site