HCNR200

HCNR200


Specifications
SKU
12607441
Details

BUY HCNR200 https://www.utsource.net/itm/p/12607441.html

Parameter Symbol Min Typ Max Unit Description
Supply Voltage VDD 4.5 5 5.5 V Operating supply voltage
Supply Current IDD - 10 - mA Quiescent current
Output Photocurrent IOUT - 100 - 渭A Photocurrent output at 10 mA LED forward current and 5 V supply
LED Forward Voltage VF 1.1 1.3 1.5 V LED forward voltage at 20 mA
LED Reverse Voltage VR - 5 7 V Maximum reverse voltage
LED Reverse Current IR - 1 10 渭A Reverse leakage current at maximum reverse voltage
Output Dark Current ID - 1 10 nA Photocurrent output when no light is incident on the photodiode
Output Capacitance CO - 5 10 pF Output capacitance at 0 V
Isolation Resistance RISO 100 - - M惟 Electrical isolation resistance between input and output
Operating Temperature TOPR -40 - 85 掳C Operating temperature range
Storage Temperature TSTG -65 - 150 掳C Storage temperature range

Instructions for Using the HCNR200

  1. Power Supply:

    • Connect the VDD pin to a stable 5V power supply.
    • Ensure the ground (GND) pin is connected to the system ground.
  2. LED Operation:

    • Apply a forward current to the LED by connecting it to a current source or a resistor in series with the supply voltage.
    • The typical forward current is 10 mA, but it can be adjusted based on the required output photocurrent.
  3. Photodiode Output:

    • The photodiode generates a photocurrent proportional to the light intensity from the LED.
    • Connect the photodiode output to a transimpedance amplifier to convert the photocurrent into a voltage signal.
  4. Isolation:

    • The HCNR200 provides electrical isolation between the input (LED) and output (photodiode) sides.
    • Ensure that the isolation resistance is maintained by avoiding high humidity and contaminants.
  5. Temperature Considerations:

    • Operate the device within the specified temperature range (-40掳C to 85掳C).
    • Store the device in a dry environment within the storage temperature range (-65掳C to 150掳C).
  6. Handling:

    • Handle the device with care to avoid damage to the leads and the internal components.
    • Use proper ESD (Electrostatic Discharge) precautions to prevent damage from static electricity.
  7. Testing:

    • Before integrating the HCNR200 into a circuit, test it using a known current source and a transimpedance amplifier to verify its performance.

By following these instructions, you can ensure reliable operation of the HCNR200 in your application.