Details
BUY IRL2910 https://www.utsource.net/itm/p/12607453.html
| Parameter | Symbol | Min | Typical | Max | Unit | Conditions |
|---|---|---|---|---|---|---|
| Drain-Source Voltage | VDS | - | 55 | - | V | |
| Gate-Source Voltage | VGS | - | 卤20 | - | V | |
| Continuous Drain Current | ID | - | 34 | - | A | TC = 25掳C, RDS(on) = 0.007 惟 |
| Pulse Drain Current | ID(p) | - | 68 | - | A | TC = 25掳C, tp = 10 ms, Duty Cycle = 1% |
| Gate Charge | QG | - | 110 | - | nC | VGS = 10 V, ID = 34 A |
| Input Capacitance | Ciss | - | 2300 | - | pF | VDS = 25 V, f = 1 MHz |
| Output Capacitance | Coss | - | 480 | - | pF | VDS = 25 V, f = 1 MHz |
| Reverse Transfer Capacitance | Crss | - | 160 | - | pF | VDS = 25 V, f = 1 MHz |
| Drain-Source On-State Resistance | RDS(on) | - | 0.007 | - | 惟 | VGS = 10 V, ID = 34 A, TJ = 25掳C |
| Gate-Source Threshold Voltage | VGS(th) | 1.0 | 1.5 | 2.0 | V | ID = 250 渭A, TJ = 25掳C |
| Total Power Dissipation | PTOT | - | 160 | - | W | TC = 25掳C |
| Junction Temperature | TJ | - | - | 150 | 掳C | |
| Storage Temperature Range | TSTG | -55 | - | 150 | 掳C |
Instructions for Use:
Handling and Storage:
- Store the IRL2910 in a dry, cool place to prevent moisture damage.
- Handle with care to avoid static discharge which can damage the device.
Mounting:
- Ensure proper heat sinking to manage the thermal resistance and maintain the junction temperature within safe limits.
- Use a thermal interface material (TIM) between the device and the heat sink for better thermal conductivity.
Biasing:
- Apply the gate-source voltage (VGS) carefully to avoid exceeding the maximum ratings.
- Use a gate resistor to control the switching speed and reduce electromagnetic interference (EMI).
Operation:
- Ensure the drain current (ID) does not exceed the continuous or pulse current ratings.
- Monitor the power dissipation (PTOT) to prevent overheating.
Testing:
- Test the device under controlled conditions to verify its performance parameters.
- Use appropriate test equipment and follow safety guidelines to avoid damage.
Safety:
- Always disconnect power before handling the device.
- Follow all relevant safety standards and guidelines when designing circuits that include the IRL2910.
View more about IRL2910 on main site