Details
BUY IRFS730 https://www.utsource.net/itm/p/12607485.html
| Parameter | Symbol | Conditions | Min | Typical | Max | Unit |
|---|---|---|---|---|---|---|
| Drain-Source Voltage | VDS | - | - | - | 200 | V |
| Gate-Source Voltage | VGS | - | -15 | - | +20 | V |
| Continuous Drain Current (TC = 25掳C) | ID | - | - | - | 4.9 | A |
| Continuous Drain Current (TC = 100掳C) | ID | - | - | - | 3.5 | A |
| Pulse Drain Current (TC = 25掳C, tp = 10 ms, duty cycle = 1%) | IDpeak | - | - | - | 14.7 | A |
| Power Dissipation (TC = 25掳C) | PD | - | - | - | 62 | W |
| Junction Temperature | TJ | - | - | - | 150 | 掳C |
| Storage Temperature Range | TSTG | - | -65 | - | 150 | 掳C |
| Total Device Dissipation (TA = 25掳C) | PTOT | - | - | - | 62 | W |
| RDS(on) at VGS = 10V | RDS(on) | ID = 4.9A | - | 0.55 | - | 惟 |
| Input Capacitance | Ciss | f = 1 MHz | - | 1200 | - | pF |
| Output Capacitance | Coss | f = 1 MHz | - | 180 | - | pF |
| Reverse Transfer Capacitance | Crss | f = 1 MHz | - | 120 | - | pF |
| Gate Charge | QG | VGS = 15V, IG = 0.5A | - | 22 | - | nC |
Instructions for Use:
Mounting and Handling:
- Ensure that the device is handled with care to avoid mechanical stress.
- Mount the device on a heatsink if operating at high power levels to maintain junction temperature within safe limits.
Electrical Connections:
- Connect the drain (D), source (S), and gate (G) terminals correctly.
- Ensure that the gate-source voltage (VGS) does not exceed the maximum ratings to prevent damage.
Thermal Management:
- Monitor the junction temperature (TJ) to ensure it remains below 150掳C.
- Use appropriate thermal management techniques such as heatsinks or forced air cooling for high-power applications.
Pulse Operation:
- For pulse operation, ensure that the pulse duration and duty cycle do not exceed the specified limits to avoid overheating.
Storage:
- Store the device in a dry environment within the storage temperature range (-65掳C to 150掳C).
Testing:
- When testing the device, use the typical values provided as a reference for expected performance under standard conditions.
Safety:
- Always follow safety guidelines when handling and operating high-voltage and high-current devices.
- Use appropriate protective equipment and follow all relevant safety standards.
View more about IRFS730 on main site