Parameter Description Min Typ Max Unit
Input Voltage (VIN) Operating input voltage range 2.7 - 5.5 V
Output Voltage (VOUT) Fixed output voltage - 3.3 - V
Output Current (IOUT) Continuous output current - 100 300 mA
Quiescent Current (IQ) Supply current during operation - 30 - 渭A
Dropout Voltage (VDROP) Typical dropout voltage at IOUT = 300mA - 400 - mV
Power Dissipation (PD) Maximum power dissipation - - 625 mW
Operating Temperature (TOPR) Operating ambient temperature range -40 - 85 掳C
Storage Temperature (TSTG) Storage temperature range -55 - 150 掳C

Instructions for BM28720MUV-E2

  1. Input Voltage:

    • Ensure the input voltage is within the specified range of 2.7V to 5.5V to avoid damage to the device.
  2. Output Voltage:

    • The device provides a fixed output voltage of 3.3V. No external components are required to set this voltage.
  3. Output Current:

    • The device can supply up to 300mA continuously. For loads requiring higher currents, consider using an appropriate heat sink or another regulator capable of handling higher currents.
  4. Quiescent Current:

    • The quiescent current is typically 30渭A, which helps in maintaining low power consumption when the regulator is active but not supplying significant load current.
  5. Dropout Voltage:

    • At full load (300mA), the typical dropout voltage is 400mV. Ensure that the input voltage exceeds the sum of the output voltage and dropout voltage to maintain regulation.
  6. Power Dissipation:

    • The maximum power dissipation is 625mW. Keep the operating conditions within this limit to prevent overheating and potential damage.
  7. Operating Temperature:

    • The device operates reliably between -40掳C and 85掳C. Avoid exposing the device to temperatures outside this range to ensure proper functionality.
  8. Storage Temperature:

    • Store the device in environments where temperatures range from -55掳C to 150掳C to prevent degradation of performance characteristics.
  9. Mounting and Layout:

    • Use recommended PCB layout guidelines to ensure optimal thermal performance and electrical characteristics. Proper grounding and decoupling capacitors should be used as specified in the datasheet.
  10. Handling Precautions:

    • Follow ESD (Electrostatic Discharge) precautions when handling the device to avoid damage.
(For reference only)