Details
BUY TOP265KG https://www.utsource.net/itm/p/12607575.html
| Parameter | Symbol | Min | Typ | Max | Unit | Description |
|---|---|---|---|---|---|---|
| Input Voltage | VIN | 100 | - | 277 | V | Operating input voltage range |
| Output Voltage | VOUT | - | 5 | - | V | Typical output voltage |
| Output Current | IOUT | - | 5.5 | - | A | Maximum continuous output current |
| Switching Frequency | fSW | - | 132 | - | kHz | Fixed switching frequency |
| Power Dissipation | PD | - | - | 80 | W | Maximum power dissipation at 25掳C ambient temperature |
| Efficiency | 畏 | - | 88 | - | % | Typical efficiency at full load |
| Standby Power | Pstand | - | 0.3 | - | W | Typical standby power consumption |
| Start-Up Time | tSTART | - | 400 | - | ms | Typical start-up time from power-on to regulation |
| Thermal Shutdown | TSD | - | 160 | - | 掳C | Thermal shutdown temperature |
| Protection Features | - | - | - | - | - | Overvoltage protection, undervoltage lockout, short-circuit protection |
Instructions for Using TOP265KG
Input Voltage (VIN):
- Ensure the input voltage is within the specified range of 100V to 277V.
- Use appropriate input filtering and transient protection to avoid damage.
Output Voltage (VOUT):
- The typical output voltage is 5V. Adjust the feedback network if a different output voltage is required.
- Verify the output voltage with a multimeter before connecting the load.
Output Current (IOUT):
- The maximum continuous output current is 5.5A. Ensure the load does not exceed this limit to prevent overheating or damage.
- Use a heatsink if operating near the maximum current to improve thermal performance.
Switching Frequency (fSW):
- The fixed switching frequency is 132kHz. This is optimized for efficiency and EMI performance.
- Do not attempt to modify the switching frequency as it can affect performance and reliability.
Power Dissipation (PD):
- The maximum power dissipation is 80W at 25掳C ambient temperature.
- Use adequate cooling solutions (heatsinks, fans) if operating in high-temperature environments.
Efficiency (畏):
- The typical efficiency at full load is 88%. Monitor the efficiency to ensure optimal performance.
- High efficiency reduces heat generation and improves overall system reliability.
Standby Power (Pstand):
- The typical standby power consumption is 0.3W. This is important for energy-saving applications.
- Ensure the standby power is within acceptable limits for your application.
Start-Up Time (tSTART):
- The typical start-up time from power-on to regulation is 400ms.
- Allow sufficient time for the device to stabilize before connecting the load.
Thermal Shutdown (TSD):
- The thermal shutdown temperature is 160掳C. The device will automatically shut down to prevent damage.
- Ensure proper ventilation and cooling to avoid reaching this temperature.
Protection Features:
- The device includes overvoltage protection, undervoltage lockout, and short-circuit protection.
- These features help protect the device and connected components from faults and damage.
Additional Notes:
- Always refer to the datasheet for detailed specifications and application notes.
- Follow good PCB layout practices to minimize noise and improve performance.
- Regularly inspect the device and connections for signs of wear or damage.
View more about TOP265KG on main site