| Parameter | Symbol | Min | Typ | Max | Unit | Conditions/Notes |
|---|---|---|---|---|---|---|
| Reverse Breakdown Voltage | VR(BR) | - | 200 | - | V | @ IR = 1mA |
| Maximum Reverse Current | IR | - | 1 | 10 | 渭A | @ VR = 200V |
| Maximum Clamping Voltage | VC | - | 330 | - | V | @ IP = 1A |
| Peak Pulse Current | IPP | - | 10 | - | A | @ tp = 8.3/42渭s |
| Operating Temperature | TA | -65 | - | 150 | 掳C | Storage and operation |
| Storage Temperature | TSTG | -65 | - | 150 | 掳C | |
| Junction Capacitance | CJ | - | 1.5 | - | pF | @ VR = 0V, f = 1MHz |
| Mounting Force | FM | - | 1.0 | 5.0 | N | Axial lead, each side |
Instructions for Use:
Handling and Storage:
- Store the device in a dry, cool place to prevent moisture damage.
- Handle with care to avoid mechanical stress on the leads and body.
Mounting:
- Apply a mounting force of 1.0 to 5.0 N to each axial lead to ensure proper contact and mechanical stability.
- Avoid excessive bending or twisting of the leads during installation.
Electrical Connections:
- Ensure that the reverse voltage does not exceed 200V to prevent breakdown.
- Keep the reverse current below 10 渭A to avoid overheating and potential damage.
- For pulse applications, do not exceed the peak pulse current of 10A for durations of 8.3/42 渭s.
Thermal Management:
- The device can operate within a temperature range of -65掳C to 150掳C. Ensure adequate heat dissipation if operating at high temperatures.
- Avoid exposing the device to temperatures outside the storage range of -65掳C to 150掳C.
Testing:
- When testing the device, use appropriate test equipment and follow safety guidelines to prevent damage to the device and personnel.
Environmental Considerations:
- The device is RoHS compliant and suitable for use in environmentally conscious designs.
- Follow local regulations for disposal and recycling of electronic components.
View more about 1SMA5923BT3G on main site