Details
BUY M51995FP https://www.utsource.net/itm/p/12607633.html
| Parameter | Symbol | Min | Typ | Max | Unit | Description |
|---|---|---|---|---|---|---|
| Supply Voltage | VCC | 4.75 | 5.0 | 5.25 | V | Operating voltage range |
| Output Current (Per Channel) | IO | - | 200 | - | mA | Maximum output current per channel |
| Number of Channels | N | - | 16 | - | - | Number of output channels |
| Operating Temperature | TOPR | -40 | - | 85 | 掳C | Operating temperature range |
| Storage Temperature | TSTG | -55 | - | 150 | 掳C | Storage temperature range |
| Input Voltage Range | VIN | 0 | - | 5.5 | V | Input voltage range |
| Leakage Current | ILK | - | 1 | - | 渭A | Leakage current per channel |
| Power Dissipation | PD | - | 1000 | - | mW | Maximum power dissipation |
| Rise Time | tr | - | 50 | - | ns | Rise time (typical) |
| Fall Time | tf | - | 50 | - | ns | Fall time (typical) |
| Propagation Delay | tPD | - | 100 | - | ns | Propagation delay (typical) |
| Enable Input Low Level | VIL | 0 | 0.8 | - | V | Enable input low level |
| Enable Input High Level | VIH | - | 2.0 | 5.5 | V | Enable input high level |
Instructions for Using M51995FP
Power Supply:
- Ensure the supply voltage (VCC) is within the specified range of 4.75V to 5.25V.
- Connect the VCC pin to a stable power source.
Output Configuration:
- The M51995FP has 16 output channels, each capable of sourcing up to 200mA of current.
- Connect the load to the appropriate output pins and ensure the total current does not exceed the maximum rating.
Temperature Considerations:
- Operate the device within the temperature range of -40掳C to 85掳C for reliable performance.
- Store the device in an environment with temperatures between -55掳C and 150掳C.
Input Voltage:
- Apply input signals within the range of 0V to 5.5V to avoid damage to the device.
- Use the enable input (EN) to control the operation of the device. Set the enable input to a high level (2.0V to 5.5V) to activate the outputs, and to a low level (0V to 0.8V) to disable them.
Leakage Current:
- Each output channel may have a leakage current of up to 1渭A. Account for this when designing your circuit to ensure accurate current measurements.
Power Dissipation:
- The device can dissipate up to 1000mW of power. Ensure proper heat dissipation to prevent overheating, especially when operating at high currents or in high ambient temperatures.
Timing Parameters:
- The rise time (tr) and fall time (tf) are typically 50ns, and the propagation delay (tPD) is typically 100ns. These parameters should be considered when designing timing-critical applications.
Handling and Storage:
- Handle the device with care to avoid static damage. Use proper ESD protection when handling the device.
- Store the device in a dry, cool place to prevent moisture damage.
By following these guidelines, you can ensure optimal performance and reliability of the M51995FP in your application.
(For reference only)View more about M51995FP on main site