Parameter Symbol Conditions Min Typ Max Unit
Forward Voltage VF IF = 20 mA - 1.2 1.6 V
Reverse Breakdown Voltage VR IR = 1 mA 5 - 7 V
Reverse Current IR VR = 5 V - 10 100 渭A
Output Current (Low) IOL VCE = 3 V, TA = 25掳C - 10 15 mA
Output Current (High) IOH VCE = -0.4 V, TA = 25掳C - -10 -15 mA
Propagation Delay Time tpd VCC = 5 V, TA = 25掳C 1 2 3 渭s
Rise Time tr VCC = 5 V, TA = 25掳C - 0.5 1 渭s
Fall Time tf VCC = 5 V, TA = 25掳C - 0.5 1 渭s
Operating Temperature Range TA - -40 - 85 掳C
Storage Temperature Range TSTG - -65 - 150 掳C

Instructions for Use:

  1. Power Supply:

    • Ensure the supply voltage (VCC) is within the specified range to avoid damage.
    • Typical operating voltage is 5 V.
  2. Forward Current:

    • The forward current (IF) should be kept within the specified limits to prevent overheating and ensure reliable operation.
    • Typical forward current is 20 mA.
  3. Reverse Voltage:

    • Do not exceed the reverse breakdown voltage (VR) to avoid damage to the device.
    • Typical reverse breakdown voltage is 7 V.
  4. Output Current:

    • When the output is low, the output current (IOL) should be within the specified range to ensure proper sinking capability.
    • When the output is high, the output current (IOH) should be within the specified range to ensure proper sourcing capability.
  5. Propagation Delay:

    • The propagation delay time (tpd) is the time it takes for the output to change state after the input changes.
    • Typical propagation delay is 2 渭s.
  6. Rise and Fall Times:

    • The rise time (tr) and fall time (tf) are the times it takes for the output to transition from low to high and high to low, respectively.
    • Typical values are 0.5 渭s for both rise and fall times.
  7. Temperature Considerations:

    • Operate the device within the specified temperature range (TA) to ensure reliable performance.
    • Store the device within the storage temperature range (TSTG) to prevent damage.
  8. Handling:

    • Handle the device with care to avoid static damage.
    • Follow ESD (Electrostatic Discharge) precautions during handling and installation.
  9. Mounting:

    • Ensure proper mounting to maintain mechanical integrity and thermal performance.
    • Use appropriate PCB layout and soldering techniques to ensure reliable connections.
  10. Testing:

    • Test the device under the specified conditions to verify its performance.
    • Use appropriate test equipment and procedures to avoid damage.