| Parameter | Symbol | Min | Typ | Max | Unit | Conditions |
|---|---|---|---|---|---|---|
| Input Voltage | VIN | 85 | - | 265 | VAC | Continuous |
| Output Voltage | VOUT | 5 | - | 12 | VDC | Adjustable |
| Output Current | IOUT | - | 1 | - | A | Adjustable |
| Switching Frequency | fSW | 65 | 130 | - | kHz | Typical at nominal conditions |
| Efficiency | 畏 | - | 85 | - | % | At full load, nominal input voltage |
| Power Dissipation | PD | - | - | 1.5 | W | Maximum at full load, nominal input voltage |
| Operating Temperature | Toper | -40 | - | 85 | 掳C | Storage and operation |
| Storage Temperature | Tstg | -55 | - | 125 | 掳C | Storage only |
| Humidity | RH | 0 | - | 95 | % | Non-condensing |
| Isolation Voltage | VIso | - | - | 4000 | VAC | 1 minute, 50/60 Hz |
| Leakage Current | ILK | - | - | 0.25 | mA | At maximum isolation voltage |
| No-Load Consumption | PNL | - | - | 0.3 | W | At nominal input voltage |
| Surge Input Voltage | Vsurge | 297 | - | - | VAC | 10 ms, 50/60 Hz |
| Inrush Current | Iinrush | - | - | 20 | A | Peak value, cold start |
| EMI Compliance | - | - | - | - | - | Meets EN55022 Class B |
Instructions for Use:
Input Connection:
- Connect the AC input to the designated input terminals.
- Ensure the input voltage is within the specified range (85VAC to 265VAC).
Output Configuration:
- Adjust the output voltage using the provided trimmer potentiometer or external resistors.
- Set the output current limit to protect the load and power supply.
Mounting:
- Mount the TOP234Y on a heatsink if operating at high temperatures or under heavy loads.
- Ensure adequate ventilation to maintain operating temperature within the specified range (-40掳C to 85掳C).
Surge Protection:
- Use appropriate surge protection devices to handle transient voltages up to 297VAC for 10 ms.
EMI Filtering:
- Install EMI filters to ensure compliance with EN55022 Class B standards.
Isolation:
- Verify that the isolation voltage meets the required safety standards (4000VAC for 1 minute).
Testing:
- Test the power supply under no-load and full-load conditions to ensure it meets the efficiency and performance specifications.
Storage:
- Store the device in a dry, non-condensing environment within the storage temperature range (-55掳C to 125掳C).
Safety:
- Follow all safety guidelines and regulations when handling and installing the power supply to prevent electrical shock and damage.