Details
BUY TSA20N50M 20A 500V https://www.utsource.net/itm/p/12607843.html
| Parameter | Symbol | Value | Unit | Description |
|---|---|---|---|---|
| Input Voltage | V_IN | 500 | V | Maximum input voltage |
| Continuous Current | I_CONT | 20 | A | Continuous current rating |
| Peak Current | I_PEAK | 40 | A | Peak current for short duration |
| Power Dissipation | P_DISS | 100 | W | Maximum power dissipation |
| Junction Temperature | T_J | -40 to 150 | °C | Operating temperature range |
| Storage Temperature | T_STG | -55 to 150 | °C | Storage temperature range |
| Insulation Resistance | R_INS | 1000 | MΩ | Minimum insulation resistance |
Instructions:
Installation:
- Ensure that the device is installed in an area with adequate ventilation to prevent overheating.
- Follow all safety guidelines when handling high voltage components.
Operation:
- Do not exceed the maximum input voltage of 500V to avoid damage to the component.
- Keep the continuous current within 20A; exceeding this can lead to overheating and potential failure.
Handling:
- Use appropriate ESD (Electrostatic Discharge) protection measures when handling the component.
- Avoid exposing the component to environments outside the specified storage temperature range (-55°C to 150°C).
Maintenance:
- Regularly inspect connections and mounting points for signs of wear or damage.
- Refer to the manufacturer’s specifications for any maintenance procedures specific to this model.
View more about TSA20N50M 20A 500V on main site