| Parameter | Symbol | Conditions | Min | Typical | Max | Unit |
|---|---|---|---|---|---|---|
| Supply Voltage | Vcc | 4.5 | 30 | V | ||
| Output Voltage Range | Vout | Vcc = 10V | 0 | 10 | V | |
| Quiescent Current | IQ | Vcc = 10V | 2.5 | mA | ||
| Output Impedance | Zout | f = 1kHz | 1 | 惟 | ||
| Temperature Coefficient | TC | Vcc = 10V, 25掳C to 85掳C | 5 | ppm/掳C | ||
| Initial Accuracy | IA | Vcc = 10V, 25掳C | -0.1 | +0.1 | % | |
| Line Regulation | LR | Vcc = 4.5V to 30V | 10 | ppm/V | ||
| Load Regulation | LLR | RL = 0惟 to 1k惟 | 10 | ppm/mA | ||
| Operating Temperature | Toper | -40 | 125 | 掳C |
Instructions for Use:
Supply Voltage (Vcc):
- The AD582KD operates over a wide supply voltage range from 4.5V to 30V. Ensure the supply voltage is within this range to avoid damage to the device.
Output Voltage Range (Vout):
- The output voltage can be adjusted from 0V to the supply voltage (Vcc). For example, with a 10V supply, the output can range from 0V to 10V.
Quiescent Current (IQ):
- The quiescent current is typically 2.5mA at a supply voltage of 10V. This value should be considered when designing power supply circuits to ensure efficient operation.
Output Impedance (Zout):
- The output impedance is very low, typically 1惟 at 1kHz. This ensures that the output voltage remains stable even under varying load conditions.
Temperature Coefficient (TC):
- The temperature coefficient is 5 ppm/掳C, indicating the change in output voltage per degree Celsius over the operating temperature range from 25掳C to 85掳C.
Initial Accuracy (IA):
- The initial accuracy of the AD582KD is 卤0.1% at 25掳C and a supply voltage of 10V. This ensures high precision in applications requiring accurate voltage references.
Line Regulation (LR):
- The line regulation is 10 ppm/V, meaning the output voltage changes by 10 parts per million for each volt change in the supply voltage.
Load Regulation (LLR):
- The load regulation is 10 ppm/mA, indicating the change in output voltage for each milliampere change in load current.
Operating Temperature (Toper):
- The device is designed to operate over a wide temperature range from -40掳C to 125掳C, making it suitable for a variety of environmental conditions.
Additional Notes:
- Always ensure proper decoupling capacitors are used to stabilize the supply voltage and reduce noise.
- Refer to the datasheet for detailed information on pin configurations, package types, and application notes.