Details
BUY B60H100G https://www.utsource.net/itm/p/12607921.html
| Parameter | Symbol | Min | Typ | Max | Unit | Description |
|---|---|---|---|---|---|---|
| Breakdown Voltage | V(BR) | - | 600 | - | V | Reverse breakdown voltage |
| Forward Voltage | V(F) | 1.2 | 1.5 | 2.0 | V @ 10A | Forward voltage at 10A |
| Peak Surge Current | I(TM) | - | 400 | - | A | Non-repetitive peak surge current |
| Average Rectified Current | I(F(AV)) | 100 | - | - | A | Average rectified forward current |
| Junction Temperature | T(J) | -40 | - | 150 | 掳C | Operating junction temperature |
| Storage Temperature | T(STG) | -55 | - | 150 | 掳C | Storage temperature range |
| Thermal Resistance | R(胃JC) | - | 1.0 | - | 掳C/W | Junction to case thermal resistance |
| Reverse Recovery Time | t(rr) | - | 35 | - | ns | Reverse recovery time |
Instructions for Use:
Mounting:
- Ensure proper heat sinking to maintain the junction temperature within the specified limits.
- Use appropriate mounting hardware to secure the device.
Electrical Connections:
- Connect the anode and cathode terminals correctly to avoid reverse polarity, which can lead to device failure.
- Use heavy-gauge wires or bus bars for high current applications to minimize resistance and voltage drop.
Thermal Management:
- Monitor the junction temperature to ensure it does not exceed 150掳C.
- Use forced air cooling or liquid cooling if necessary to manage heat dissipation.
Surge Handling:
- The device can handle peak surge currents up to 400A non-repetitively. Ensure that the surge conditions do not exceed this limit to prevent damage.
Storage:
- Store the device in a dry environment within the temperature range of -55掳C to 150掳C.
- Avoid exposure to corrosive environments.
Testing:
- Perform regular testing to ensure the device is functioning within its specified parameters.
- Use appropriate test equipment and follow safety guidelines to avoid electrical hazards.
Handling:
- Handle the device with care to avoid mechanical stress or damage.
- Use ESD (Electrostatic Discharge) protection when handling the device to prevent damage from static electricity.
View more about B60H100G on main site