Details
BUY DS1220Y https://www.utsource.net/itm/p/12607940.html
| Parameter | Symbol | Conditions | Min | Typ | Max | Unit |
|---|---|---|---|---|---|---|
| Operating Voltage | Vcc | 2.5 | 5 | 5.5 | V | |
| Standby Current | Icc | Vcc = 5V | - | 1 | 2 | 渭A |
| Active Current | Icc | Vcc = 5V, 100 kHz | - | 3 | 6 | mA |
| Output Low Voltage | Vol | Iol = 16mA | 0.4 | - | - | V |
| Output High Voltage | Voh | Ioh = -4mA | - | - | 4.5 | V |
| Input Low Voltage | Vil | - | 1.5 | 2 | V | |
| Input High Voltage | Vih | 3 | 3.5 | - | V | |
| Maximum Clock Frequency | fmax | - | 100 | 400 | kHz | |
| Maximum Data Retention Time | tret | Vcc = 5V | - | - | 10 | years |
Instructions for DS1220Y
Power Supply:
- Ensure the operating voltage (Vcc) is within the range of 2.5V to 5.5V.
- The typical operating voltage is 5V.
Current Consumption:
- In standby mode, the current consumption (Icc) should be between 1渭A and 2渭A at 5V.
- In active mode, the current consumption can range from 3mA to 6mA at 5V and 100kHz.
Output Levels:
- For output low (Vol), the voltage should not exceed 0.4V when the output current (Iol) is 16mA.
- For output high (Voh), the voltage should be at least 4.5V when the output current (Ioh) is -4mA.
Input Levels:
- For input low (Vil), the voltage should be between 1.5V and 2V.
- For input high (Vih), the voltage should be between 3V and 3.5V.
Clock Frequency:
- The maximum clock frequency (fmax) can range from 100kHz to 400kHz.
Data Retention:
- The device can retain data for up to 10 years when powered at 5V.
Handling and Storage:
- Store the device in a dry environment to prevent moisture damage.
- Handle with care to avoid static discharge which can damage the device.
Schematic and Layout:
- Ensure proper decoupling capacitors are used near the power supply pins to stabilize the voltage.
- Follow the recommended layout guidelines provided by the manufacturer to ensure optimal performance.
Programming:
- Use the appropriate programming protocol (e.g., I2C) to communicate with the device.
- Refer to the datasheet for specific commands and sequences required for reading and writing data.
Testing:
- Before deploying the device, test it under various conditions to ensure it meets the specified parameters.
- Verify the functionality of the device using a known good setup to rule out any external issues.