| Parameter | Symbol | Min | Typ | Max | Unit | Conditions |
|---|---|---|---|---|---|---|
| Continuous Drain Current | ID | - | 30 | - | A | Tc = 25掳C |
| Pulse Drain Current | IDM | - | 45 | - | A | Tc = 25掳C, tp = 10 ms |
| Continuous Gate-Source Voltage | VGS | -15 | - | 15 | V | - |
| Drain-Source Breakdown Voltage | BVDSS | 60 | - | - | V | IG = 250 渭A, Tc = 25掳C |
| Gate-Threshold Voltage | VGS(th) | 1.0 | 1.5 | 2.0 | V | ID = 1 mA, Tc = 25掳C |
| On-State Resistance | RDS(on) | - | 5.5 | - | m惟 | VGS = 4.5 V, ID = 30 A, Tc = 25掳C |
| Total Power Dissipation | PD | - | - | 280 | W | Tc = 25掳C |
| Junction Temperature | TJ | - | - | 175 | 掳C | - |
| Storage Temperature Range | Tstg | -55 | - | 150 | 掳C | - |
Instructions for Use:
Handling Precautions:
- Handle the BUW11AF with care to avoid damage to the pins and the silicon.
- Use appropriate ESD (Electrostatic Discharge) protection measures to prevent damage from static electricity.
Mounting:
- Ensure proper thermal management by using a heatsink if necessary, especially when operating at high power levels.
- Follow recommended soldering profiles to avoid thermal shock and ensure reliable connections.
Biasing:
- Apply the gate-source voltage (VGS) within the specified limits to avoid damaging the device.
- Ensure the drain-source voltage (VDS) does not exceed the breakdown voltage (BVDSS).
Current Limiting:
- Do not exceed the continuous drain current (ID) or pulse drain current (IDM) ratings.
- Use external current limiting resistors if necessary to protect the device.
Thermal Considerations:
- Monitor the junction temperature (TJ) to ensure it stays within the safe operating range.
- Use adequate cooling solutions to dissipate heat effectively.
Storage:
- Store the BUW11AF in a dry, cool environment to prevent moisture damage.
- Keep the device in its original packaging until ready for use.
Testing:
- Perform initial testing under controlled conditions to verify the device is functioning correctly.
- Use appropriate test equipment and follow safety guidelines to avoid damage to the device or injury.