BUY LM1951T https://www.utsource.net/itm/p/12607987.html
| Parameter | Symbol | Min | Typ | Max | Unit |
|---|---|---|---|---|---|
| Input Voltage | V_IN | 4.5 | - | 40 | V |
| Output Voltage | V_OUT | 1.23 | - | 37 | V |
| Output Current | I_OUT | - | 100 | 150 | mA |
| Quiescent Current | I_Q | - | 40 | - | 渭A |
| Dropout Voltage | V_DO | - | 1.2 | - | V |
| Load Regulation | - | - | 0.01 | - | %/mA |
| Line Regulation | - | - | 0.005 | - | %/V |
| Temperature Coefficient | - | - | 35 | - | ppm/掳C |
| Operating Temperature | T_OP | -40 | - | 125 | 掳C |
| Storage Temperature | T_STG | -65 | - | 150 | 掳C |
| Thermal Resistance (胃JA) | - | - | 150 | - | 掳C/W |
Instructions for Use:
Input Voltage (V_IN):
- Ensure the input voltage is within the range of 4.5V to 40V.
- Avoid exceeding the maximum input voltage to prevent damage to the device.
Output Voltage (V_OUT):
- The output voltage can be adjusted from 1.23V to 37V using external resistors.
- Use the formula ( V_ = 1.23 left(1 + fracright) ) to set the desired output voltage, where ( R_1 ) and ( R_2 ) are the resistor values.
Output Current (I_OUT):
- The typical output current is 100mA, with a maximum of 150mA.
- Ensure the load does not exceed the maximum output current to avoid overheating or damage.
Quiescent Current (I_Q):
- The quiescent current is typically 40渭A.
- This low current draw makes the LM1951T suitable for battery-powered applications.
Dropout Voltage (V_DO):
- The dropout voltage is typically 1.2V.
- Ensure the input voltage is at least 1.2V higher than the output voltage to maintain regulation.
Load Regulation:
- The load regulation is 0.01% per milliampere.
- This indicates that the output voltage will change by 0.01% for every 1mA change in load current.
Line Regulation:
- The line regulation is 0.005% per volt.
- This indicates that the output voltage will change by 0.005% for every 1V change in input voltage.
Temperature Coefficient:
- The temperature coefficient is 35ppm/掳C.
- This means the output voltage will change by 35 parts per million for every degree Celsius change in temperature.
Operating Temperature (T_OP):
- The operating temperature range is from -40掳C to 125掳C.
- Ensure the device operates within this range to avoid performance degradation or damage.
Storage Temperature (T_STG):
- The storage temperature range is from -65掳C to 150掳C.
- Store the device within this range to prevent damage.
Thermal Resistance (胃JA):
- The thermal resistance from junction to ambient is 150掳C/W.
- Ensure adequate heat dissipation if the device is operated at high power levels or in high-temperature environments.
Additional Notes:
- Always use appropriate decoupling capacitors on the input and output to ensure stability and reduce noise.
- Refer to the datasheet for detailed application circuits and layout guidelines.
View more about LM1951T on main site