BUV28A

BUV28A


Specifications
SKU
12608113
Details

BUY BUV28A https://www.utsource.net/itm/p/12608113.html

Parameter Symbol Min Typical Max Unit
Breakdown Voltage V(BR) - 400 - V
Leakage Current I(D) (V(DS) = 450V, T(A) = 25掳C) - 100 - nA
Gate-Source Voltage V(GS) - 0 20 V
Drain-Source On-State Resistance R(DS(on)) (V(GS) = 10V, I(D) = 1A) - 0.7 -
Input Capacitance Ciss (V(DS) = 300V, f = 1MHz) - 1800 - pF
Output Capacitance Coss (V(DS) = 300V, f = 1MHz) - 100 - pF
Reverse Transfer Capacitance Crss (V(DS) = 300V, f = 1MHz) - 60 - pF
Turn-On Delay Time t(d(on)) (I(G) = 1A, I(D) = 1A) - 20 - ns
Rise Time t(r) (I(G) = 1A, I(D) = 1A) - 25 - ns
Turn-Off Delay Time t(d(off)) (I(G) = 1A, I(D) = 1A) - 25 - ns
Fall Time t(f) (I(G) = 1A, I(D) = 1A) - 20 - ns

Instructions for Using BUV28A:

  1. Power Supply:

    • Ensure that the power supply voltage does not exceed the breakdown voltage (V(BR)) of 400V.
  2. Gate Drive:

    • Apply a gate-source voltage (V(GS)) between 0V and 20V to control the on-state and off-state of the device.
    • For optimal performance, use a gate drive voltage of 10V to minimize the on-state resistance (R(DS(on))).
  3. Leakage Current:

    • Monitor the leakage current (I(D)) at high voltages to ensure it remains within the typical range of 100 nA.
  4. Capacitance Considerations:

    • Account for the input capacitance (Ciss), output capacitance (Coss), and reverse transfer capacitance (Crss) when designing the circuit to avoid unwanted oscillations and ensure stable operation.
  5. Switching Characteristics:

    • The turn-on delay time (t(d(on))), rise time (t(r)), turn-off delay time (t(d(off))), and fall time (t(f)) should be considered to optimize switching speed and efficiency.
    • Use appropriate gate drive circuits to minimize these times and reduce switching losses.
  6. Thermal Management:

    • Ensure adequate heat sinking to manage the power dissipation during operation, especially under high current conditions.
  7. Storage and Handling:

    • Store the device in a dry, cool environment to prevent moisture damage.
    • Handle the device with care to avoid static discharge, which can damage the sensitive components.
  8. Safety Precautions:

    • Always follow proper safety procedures when working with high voltages and currents.
    • Use appropriate protective equipment and ensure that the circuit is properly isolated before making any measurements or adjustments.
(For reference only)

View more about BUV28A on main site