LS05-15B12SS

LS05-15B12SS


Specifications
SKU
12608130
Details

BUY LS05-15B12SS https://www.utsource.net/itm/p/12608130.html

Parameter Description Value
Part Number Component Identifier LS05-15B12SS
Type Relay Type SPDT (Single Pole Double Throw)
Coil Voltage Voltage Required to Operate the Coil 12V DC
Coil Current Current Drawn by the Coil 38mA
Contact Form Configuration of the Relay Contacts SPDT
Contact Rating Maximum Current and Voltage the Contacts Can Handle 10A at 250V AC
Switching Capacity Maximum Power the Relay Can Switch 2500VA
Insulation Resistance Resistance Between Contacts and Coil >100M惟 at 500V DC
Dielectric Strength Voltage the Relay Can Withstand Without Breakdown 1500V AC for 1 minute
Mechanical Life Number of Operations Before Failure (No Load) 10,000,000 cycles
Electrical Life Number of Operations Before Failure (Rated Load) 100,000 cycles
Operating Temperature Range of Ambient Temperatures Where the Relay Can Function -40掳C to +85掳C
Storage Temperature Range of Temperatures for Storage -40掳C to +125掳C
Weight Mass of the Relay 15g
Dimensions Physical Size of the Relay 17.5mm x 12.5mm x 12.5mm

Instructions:

  1. Installation:

    • Ensure the relay is mounted on a flat, stable surface.
    • Use appropriate mounting hardware to secure the relay.
    • Connect the coil terminals to the control circuit using wires rated for the coil current.
  2. Wiring:

    • Connect the common (COM) terminal to the power source or load.
    • Connect the normally open (NO) and normally closed (NC) terminals to the respective parts of the circuit you want to control.
    • Ensure all connections are tight and secure to prevent arcing or loose connections.
  3. Operation:

    • Apply the rated coil voltage to activate the relay. The contacts will switch from NC to NO.
    • Remove the coil voltage to deactivate the relay. The contacts will return to their default position (NC).
  4. Maintenance:

    • Regularly inspect the relay for signs of wear or damage.
    • Clean the relay with a dry, soft cloth to remove dust and debris.
    • Replace the relay if it shows signs of failure or does not meet performance specifications.
  5. Safety:

    • Do not exceed the maximum ratings for voltage, current, and power.
    • Ensure the relay is installed in a well-ventilated area to prevent overheating.
    • Use appropriate fuses or circuit breakers to protect the circuit from overcurrent conditions.
(For reference only)