Details
BUY MCR22-8 https://www.utsource.net/itm/p/12608160.html
| Parameter | Description | Value |
|---|---|---|
| Part Number | Full part number | MCR22-8 |
| Type | Component type | Surface Mount Relay |
| Package | Package type | DIP-8 |
| Coil Voltage | Operating voltage for the relay coil | 5V, 12V, 24V |
| Coil Current | Current required to energize the relay | 30mA (at 5V) |
| Contact Form | Configuration of the relay contacts | SPDT |
| Contact Rating | Maximum current and voltage for contacts | 5A, 250VAC |
| Insulation Resistance | Minimum resistance between contacts and coil | 100M惟 at 500VDC |
| Dielectric Strength | Voltage withstand capability | 1500VAC (1 minute) |
| Operating Temperature | Range of temperatures for operation | -40掳C to +85掳C |
| Storage Temperature | Range of temperatures for storage | -55掳C to +125掳C |
| Weight | Weight of the component | 6g |
Instructions
Handling and Storage:
- Store the relay in a dry, clean environment.
- Avoid exposure to high humidity, corrosive gases, or extreme temperatures.
Mounting:
- Ensure the PCB is clean and free from contaminants before mounting.
- Use appropriate soldering techniques to avoid overheating the relay.
- Allow sufficient space around the relay for heat dissipation.
Wiring:
- Connect the coil terminals to the control circuit according to the specified coil voltage.
- Connect the contact terminals to the load circuit ensuring the current and voltage ratings are not exceeded.
Testing:
- Test the relay using a multimeter to verify continuity and insulation resistance.
- Apply the rated coil voltage to test the switching function.
Operation:
- Ensure the relay is operated within the specified temperature range.
- Regularly inspect the relay for signs of wear or damage.
Safety:
- Follow all safety guidelines when handling and testing the relay.
- Use appropriate personal protective equipment (PPE) as needed.
Disposal:
- Dispose of the relay in accordance with local environmental regulations.
View more about MCR22-8 on main site