| Parameter | Symbol | Min | Typical | Max | Unit | Notes |
|---|---|---|---|---|---|---|
| Supply Voltage | Vcc | 2.7 | - | 3.6 | V | Operating range |
| Standby Current | ISB | - | 10 | 20 | 渭A | At Vcc = 3.0V, Ta = 25掳C |
| Active Current | IOP | - | 50 | 100 | mA | During read operation, Vcc = 3.0V, Ta = 25掳C |
| Access Time | tACC | 65 | - | - | ns | From CE# low to valid output data |
| Output High Level | VOH | 2.4 | - | Vcc | V | At IOL = -4mA, Vcc = 3.0V |
| Output Low Level | VOL | 0 | - | 0.4 | V | At IOH = 4mA, Vcc = 3.0V |
| Input High Level | VIH | 2.0 | - | Vcc | V | Minimum input high level voltage |
| Input Low Level | VIL | 0 | - | 0.8 | V | Maximum input low level voltage |
| Data Retention Time | tRET | - | 20 | - | years | Data retention at Ta = 85掳C |
| Operating Temperature | Ta | -40 | - | 85 | 掳C | Industrial temperature range |
| Storage Temperature | Tstg | -65 | - | 150 | 掳C | Storage temperature range |
Instructions for Use:
Power Supply:
- Ensure the supply voltage (Vcc) is within the specified range of 2.7V to 3.6V.
- Avoid connecting the device to voltages outside this range to prevent damage.
Current Considerations:
- The standby current (ISB) should be monitored to ensure it does not exceed 20渭A to minimize power consumption.
- During active operations, the current (IOP) can reach up to 100mA, so ensure the power supply can handle this load.
Timing Parameters:
- The access time (tACC) is 65ns, which is the time from when the chip enable (CE#) goes low to when valid data is available on the outputs.
- Ensure that all timing requirements are met to avoid data corruption or incorrect operation.
Signal Levels:
- The output high level (VOH) should be at least 2.4V and can go up to the supply voltage (Vcc).
- The output low level (VOL) should be no more than 0.4V.
- Input signals should be within the specified levels (VIH and VIL) to ensure proper operation.
Environmental Conditions:
- The device is rated for industrial operating temperatures ranging from -40掳C to 85掳C.
- Store the device in a temperature range of -65掳C to 150掳C to ensure long-term reliability.
Data Retention:
- The device retains data for up to 20 years at a temperature of 85掳C. Ensure that the device is stored and operated within recommended conditions to maintain data integrity.
Handling:
- Handle the device with care to avoid static discharge, which can damage the internal circuits.
- Follow standard ESD (Electrostatic Discharge) precautions when handling and installing the device.
Mounting:
- Ensure proper mounting and soldering techniques to avoid mechanical stress and ensure reliable connections.