Details
BUY TC500ACPE https://www.utsource.net/itm/p/12608455.html
| Parameter | Description | Value | Unit |
|---|---|---|---|
| Part Number | Component Identifier | TC500ACPE | - |
| Type | Device Type | AC Power Entry Module | - |
| Input Voltage Range | Operating Voltage Range | 100 - 240 | VAC |
| Input Frequency Range | Operating Frequency Range | 50 - 60 | Hz |
| Maximum Current | Continuous Operating Current | 10 | A |
| Inrush Current | Peak Current at Power On | 30 | A |
| Power Factor | Efficiency Measure | 0.95 | - |
| Insulation Resistance | Electrical Isolation | 100 | M惟 |
| Dielectric Strength | Voltage Withstand | 2500 | VAC |
| Operating Temperature Range | Ambient Temperature | -25 to 70 | 掳C |
| Storage Temperature Range | Non-Operating Temperature | -40 to 85 | 掳C |
| Humidity Range | Relative Humidity | 5 to 95 | % (non-condensing) |
| Mounting Style | Installation Method | Panel Mount | - |
| Terminal Type | Connection Method | Screw Terminal | - |
| Terminal Pitch | Distance Between Terminals | 5.08 | mm |
| Dimensions (LxWxH) | Physical Size | 35 x 25 x 20 | mm |
| Weight | Mass | 30 | g |
| Compliance | Regulatory Standards | CE, UL, cUL | - |
Instructions for Use:
Installation:
- Ensure the ambient temperature is within the operating range (-25掳C to 70掳C).
- Mount the module securely on a panel using the provided mounting holes.
- Connect the input power lines to the screw terminals, ensuring they are tight and secure.
Operation:
- Power on the device by connecting it to the mains supply within the specified voltage and frequency ranges.
- Monitor the current draw to ensure it does not exceed the maximum continuous operating current of 10A.
Maintenance:
- Regularly inspect the connections for signs of wear or looseness.
- Clean the module with a dry cloth to remove dust and debris.
Safety Precautions:
- Do not operate the module in environments with high humidity or condensation.
- Ensure proper grounding to prevent electrical shock.
- Do not exceed the maximum inrush current to avoid damage to the module.
- Follow all local electrical codes and regulations.
Storage:
- Store the module in a dry location within the storage temperature range (-40掳C to 85掳C).
Compliance:
- The TC500ACPE is compliant with CE, UL, and cUL standards. Ensure that the installation and use comply with these standards.