IRFB4127PBF

IRFB4127PBF


Specifications
SKU
12608502
Details

BUY IRFB4127PBF https://www.utsource.net/itm/p/12608502.html

Parameter Symbol Min Typical Max Unit Conditions
Drain-Source Voltage VDS - 55 - V
Gate-Source Voltage VGS - 卤20 - V
Continuous Drain Current (TC = 25掳C) ID(25掳C) - 69 - A
Continuous Drain Current (TC = 100掳C) ID(100掳C) - 48 - A
Pulse Drain Current (TC = 25掳C, tp = 10 渭s) ID(pulsed) - 180 - A
Total Power Dissipation (TC = 25掳C) PTOT(25掳C) - 210 - W
Total Power Dissipation (TC = 100掳C) PTOT(100掳C) - 130 - W
Junction Temperature TJ - - 150 掳C
Storage Temperature Range TSTG -55 - 150 掳C
Gate Charge QG - 42 - nC VGS = 10V
Input Capacitance Ciss - 1600 - pF VDS = 25V
Output Capacitance Coss - 105 - pF VDS = 25V
Reverse Transfer Capacitance Crss - 100 - pF VDS = 25V, ID = 0A
On-State Resistance (VGS = 10V) RDS(on) - 1.7 - m惟 ID = 69A, TJ = 25掳C
On-State Resistance (VGS = 4.5V) RDS(on) - 2.5 - m惟 ID = 69A, TJ = 25掳C
Threshold Voltage VGS(th) 2.0 3.0 4.0 V ID = 250 渭A, TJ = 25掳C

Instructions for Use:

  1. Mounting and Handling:

    • Ensure proper heat sinking to manage the high power dissipation.
    • Handle the device with care to avoid damage to the leads and body.
  2. Electrical Connections:

    • Connect the drain (D), source (S), and gate (G) terminals correctly.
    • Use appropriate gate drive circuits to ensure reliable operation.
  3. Thermal Management:

    • Ensure adequate cooling to keep the junction temperature within the specified limits.
    • Use thermal paste or thermal interface materials between the device and the heatsink for better thermal conductivity.
  4. Operating Conditions:

    • Do not exceed the maximum ratings listed in the table.
    • Operate within the recommended operating conditions to ensure reliability and longevity.
  5. Storage:

    • Store the device in a dry, cool place away from direct sunlight and corrosive environments.
    • Follow ESD (Electrostatic Discharge) precautions to prevent damage.
  6. Testing:

    • Use appropriate test equipment and procedures to verify the device parameters.
    • Refer to the datasheet for detailed testing procedures and guidelines.
(For reference only)

View more about IRFB4127PBF on main site