VHCT244A

VHCT244A


Specifications
SKU
12608556
Details

BUY VHCT244A https://www.utsource.net/itm/p/12608556.html

Parameter Symbol Conditions Min Typical Max Unit
Supply Voltage VCC Operating 1.65 - 3.6 V
Input Low Voltage VIL - 0.0 - 0.8 V
Input High Voltage VIH - 2.0 - VCC V
Output Low Voltage VOL IOL = 4 mA 0.0 - 0.4 V
Output High Voltage VOH IOH = -0.4 mA 2.4 - VCC V
Propagation Delay Time (High to Low) tpdLH VCC = 3.3 V, TA = 25掳C - 3.5 - ns
Propagation Delay Time (Low to High) tpdHL VCC = 3.3 V, TA = 25掳C - 3.5 - ns
Power Dissipation PD Maximum - - 700 mW
Operating Temperature Range TA - -40 - 85 掳C
Storage Temperature Range TSTG - -65 - 150 掳C

Instructions for Use:

  1. Power Supply:

    • Ensure the supply voltage (VCC) is within the specified range of 1.65 V to 3.6 V.
    • Connect VCC to the power supply and GND to ground.
  2. Input Signals:

    • Input signals should be within the valid input voltage range: 0.0 V to 0.8 V for low logic level and 2.0 V to VCC for high logic level.
    • Avoid exceeding the maximum input voltage to prevent damage.
  3. Output Signals:

    • The output low voltage (VOL) should not exceed 0.4 V when sinking 4 mA.
    • The output high voltage (VOH) should be at least 2.4 V when sourcing -0.4 mA.
    • Ensure the load connected to the output does not exceed the maximum current ratings.
  4. Propagation Delay:

    • The propagation delay times (tpdLH and tpdHL) are typically 3.5 ns at VCC = 3.3 V and TA = 25掳C.
    • These values can vary with temperature and supply voltage.
  5. Temperature Considerations:

    • The device operates reliably within the temperature range of -40掳C to 85掳C.
    • Store the device in a temperature range of -65掳C to 150掳C to avoid damage.
  6. Power Dissipation:

    • Ensure that the power dissipation (PD) does not exceed 700 mW to prevent overheating and potential failure.
  7. Handling and Storage:

    • Handle the device with care to avoid static discharge, which can damage sensitive components.
    • Store the device in a dry, cool place to prevent moisture-related issues.
(For reference only)