Details
BUY SP485ECN-L/TR https://www.utsource.net/itm/p/12608633.html
| Parameter | Description | Value |
|---|---|---|
| Part Number | Part identification | SP485ECN-L/TR |
| Package Type | Package style | SOIC-8 |
| Supply Voltage (Vcc) | Operating voltage range | 3.0 V to 5.5 V |
| Data Rate | Maximum data transmission rate | 20 Mbps |
| Operating Temperature | Temperature range for operation | -40°C to +85°C |
| ESD Protection | Electrostatic discharge protection | ±15 kV Human Body Model |
| Driver Output Current | Maximum output current from driver pins | ±250 mA |
| Receiver Input Impedance | Receiver input impedance at logic levels | ≥12 kΩ |
| Power Dissipation | Maximum power dissipation | 175 mW |
| Standby Current | Supply current in standby mode | < 1 μA |
| Driver Enable Time | Time required for the driver to enable | 2 μs |
| Driver Disable Time | Time required for the driver to disable | 2 μs |
Instructions:
- Power Supply Connection: Connect Vcc to a stable power supply within the operating voltage range of 3.0 V to 5.5 V. Ensure GND is properly grounded.
- Signal Lines: Connect the A and B terminals to the differential signal lines for RS-485 communication.
- Driver Control: Use DE (Driver Enable) pin to control the direction of data transmission. Set DE high to enable transmission, low to receive data.
- Receiver Operation: The receiver is always active unless disabled by setting DE high. It operates on the differential signals received on A and B.
- Termination Resistors: For optimal performance, especially over long distances or in noisy environments, use termination resistors (typically 120 Ω) at each end of the bus.
- ESD Handling: Handle the device with care to avoid damage from electrostatic discharge. Follow standard ESD precautions during installation.
- Heat Management: Although the device has a maximum power dissipation of 175 mW, ensure adequate heat sinking if used in high ambient temperatures or enclosed spaces.