BTA16-800CW

BTA16-800CW


Specifications
SKU
12608638
Details

BUY BTA16-800CW https://www.utsource.net/itm/p/12608638.html

Parameter Symbol Value Unit
Rated RMS On-State Current IT(RMS) 16 A
Peak On-State Current ITSM 125 A
RMS Off-State Voltage VDRM 800 V
Non-Repetitive Peak Off-State Voltage VRRM 1200 V
On-State Voltage Drop VT 1.3 (max) V
Gate Trigger Current IG(T) 50 (max) mA
Holding Current IH 30 (max) mA
Thermal Resistance, Junction to Case R胃JC 1.5 掳C/W
Operating Temperature Range Tj -40 to 125 掳C

Instructions for BTA16-800CW

  1. Mounting:

    • Ensure proper heat sinking to maintain junction temperature within the specified range.
    • Use thermal compound between the device and the heatsink to improve thermal conductivity.
  2. Gate Drive:

    • Apply a gate trigger current (IG(T)) of at least 50 mA to ensure reliable turn-on.
    • The gate voltage should be between 4 V and 15 V for optimal performance.
  3. Current Handling:

    • Do not exceed the rated RMS on-state current (IT(RMS)) of 16 A.
    • For peak currents, do not exceed 125 A for short durations.
  4. Voltage Handling:

    • The device can handle an RMS off-state voltage (VDRM) of up to 800 V.
    • For non-repetitive peak off-state voltage, ensure it does not exceed 1200 V.
  5. Temperature Management:

    • Operate the device within the temperature range of -40掳C to 125掳C.
    • Monitor the junction temperature to avoid overheating, which can lead to premature failure.
  6. Storage and Handling:

    • Store in a dry, cool place to prevent moisture damage.
    • Handle with care to avoid mechanical stress or damage to the leads.
  7. Safety Precautions:

    • Ensure proper insulation and isolation to avoid electrical hazards.
    • Follow all relevant safety standards and guidelines when designing circuits that use this component.

By adhering to these parameters and instructions, you can ensure the reliable operation and longevity of the BTA16-800CW triac.

(For reference only)

View more about BTA16-800CW on main site