VIPER50A.

VIPER50A.


Specifications
SKU
12608668
Details

BUY VIPER50A. https://www.utsource.net/itm/p/12608668.html

Parameter Description Value
Part Number VIPER50A
Manufacturer STMicroelectronics
Type Offline Switcher IC
Package DIP-8, SOP-8
Input Voltage Operating range 120V to 265V AC
Output Power Maximum continuous output power 50W
Switching Frequency Internal oscillator frequency 65kHz
Standby Current Quiescent current in shutdown mode < 100渭A
Protection Features Overvoltage protection, overcurrent protection, thermal shutdown Yes
Operating Temperature Ambient temperature range -40掳C to 125掳C
Storage Temperature Storage temperature range -65掳C to 150掳C
Humidity Relative humidity 0% to 95% (non-condensing)
Lead Finish Matte Sn

Instructions for Use:

  1. Circuit Design:

    • Ensure the input voltage is within the specified range (120V to 265V AC).
    • Design the transformer and other components to match the output power requirements.
    • Use appropriate capacitors and diodes to filter and rectify the input voltage.
  2. Thermal Management:

    • Mount the VIPER50A on a heatsink if operating at high power levels to ensure proper heat dissipation.
    • Ensure adequate airflow around the component to prevent overheating.
  3. Protection Circuits:

    • Utilize the built-in overvoltage, overcurrent, and thermal protection features by connecting the necessary external components as per the datasheet.
    • Implement additional external protection circuits if required for specific applications.
  4. Power-On Sequence:

    • Apply the input voltage gradually to avoid inrush currents.
    • Monitor the output voltage and current during startup to ensure stable operation.
  5. Testing:

    • Test the circuit under various load conditions to verify performance and stability.
    • Check for any signs of overheating or unusual behavior during prolonged operation.
  6. Handling and Storage:

    • Handle the VIPER50A with care to avoid damage to the pins and package.
    • Store in a dry, cool environment to prevent moisture-related issues.
  7. Compliance:

    • Ensure the design complies with relevant safety and regulatory standards for power supplies.

For detailed specifications and application notes, refer to the official datasheet from STMicroelectronics.

(For reference only)

View more about VIPER50A. on main site