NC4D-P-DC5V

NC4D-P-DC5V


Specifications
SKU
12608676
Details

BUY NC4D-P-DC5V https://www.utsource.net/itm/p/12608676.html

Parameter Description Value
Part Number NC4D-P-DC5V
Type 4-Channel Relay Module
Input Voltage Operating Voltage for Control Logic DC 5V
Relay Type Electromechanical Relays (EMR)
Relay Channels Number of Independent Relay Channels 4
Contact Form Normally Open (NO) / Normally Closed (NC) NO
Contact Rating Maximum Switching Capacity 10A, 250VAC
Control Signal Input Signal to Trigger Relay TTL Level
Operating Current Current Consumption per Channel < 80mA
Isolation Voltage Isolation Between Input and Output 2500VDC
Dimensions Module Size 75mm x 35mm
Weight Module Weight 50g
**Operating Temperature Range of Ambient Temperature for Operation -10掳C to 50掳C
Storage Temperature Range of Ambient Temperature for Storage -20掳C to 70掳C
Humidity Operating Humidity Range 5% to 95% RH (Non-condensing)
Certifications Safety and Compliance Certifications CE, RoHS

Instructions

  1. Power Supply:

    • Connect the DC 5V power supply to the VCC and GND terminals on the module.
  2. Control Signals:

    • Connect the control signals from your microcontroller or logic circuit to the IN1, IN2, IN3, and IN4 terminals.
    • Apply a high signal (TTL level, typically 5V) to the input terminal to activate the corresponding relay channel.
  3. Load Connection:

    • Connect the load to the common (COM), normally open (NO), and normally closed (NC) terminals of each relay channel.
    • For normally open operation, connect the load between COM and NO.
    • For normally closed operation, connect the load between COM and NC.
  4. Grounding:

    • Ensure that the ground of the control circuit and the power supply are connected to the same ground to avoid potential issues.
  5. Mounting:

    • Mount the module securely in a well-ventilated area to ensure proper heat dissipation.
    • Avoid placing the module near sources of high temperature or humidity.
  6. Testing:

    • Before connecting the load, test the relays with a simple LED or buzzer to ensure they are functioning correctly.
    • Use a multimeter to verify the continuity of the relay contacts when activated and deactivated.
  7. Safety:

    • Do not exceed the maximum contact rating of the relays.
    • Ensure that the load is disconnected before applying power to the module.
    • Follow all safety guidelines and regulations for handling electrical components.
  8. Troubleshooting:

    • If a relay does not activate, check the control signal and power supply connections.
    • If the relay activates but the load does not operate, check the load connections and the load itself.
    • If the module overheats, ensure proper ventilation and reduce the load current if necessary.