Details
BUY NC4D-P-DC5V https://www.utsource.net/itm/p/12608676.html
| Parameter | Description | Value |
|---|---|---|
| Part Number | NC4D-P-DC5V | |
| Type | 4-Channel Relay Module | |
| Input Voltage | Operating Voltage for Control Logic | DC 5V |
| Relay Type | Electromechanical Relays (EMR) | |
| Relay Channels | Number of Independent Relay Channels | 4 |
| Contact Form | Normally Open (NO) / Normally Closed (NC) | NO |
| Contact Rating | Maximum Switching Capacity | 10A, 250VAC |
| Control Signal | Input Signal to Trigger Relay | TTL Level |
| Operating Current | Current Consumption per Channel | < 80mA |
| Isolation Voltage | Isolation Between Input and Output | 2500VDC |
| Dimensions | Module Size | 75mm x 35mm |
| Weight | Module Weight | 50g |
| **Operating Temperature | Range of Ambient Temperature for Operation | -10掳C to 50掳C |
| Storage Temperature | Range of Ambient Temperature for Storage | -20掳C to 70掳C |
| Humidity | Operating Humidity Range | 5% to 95% RH (Non-condensing) |
| Certifications | Safety and Compliance Certifications | CE, RoHS |
Instructions
Power Supply:
- Connect the DC 5V power supply to the VCC and GND terminals on the module.
Control Signals:
- Connect the control signals from your microcontroller or logic circuit to the IN1, IN2, IN3, and IN4 terminals.
- Apply a high signal (TTL level, typically 5V) to the input terminal to activate the corresponding relay channel.
Load Connection:
- Connect the load to the common (COM), normally open (NO), and normally closed (NC) terminals of each relay channel.
- For normally open operation, connect the load between COM and NO.
- For normally closed operation, connect the load between COM and NC.
Grounding:
- Ensure that the ground of the control circuit and the power supply are connected to the same ground to avoid potential issues.
Mounting:
- Mount the module securely in a well-ventilated area to ensure proper heat dissipation.
- Avoid placing the module near sources of high temperature or humidity.
Testing:
- Before connecting the load, test the relays with a simple LED or buzzer to ensure they are functioning correctly.
- Use a multimeter to verify the continuity of the relay contacts when activated and deactivated.
Safety:
- Do not exceed the maximum contact rating of the relays.
- Ensure that the load is disconnected before applying power to the module.
- Follow all safety guidelines and regulations for handling electrical components.
Troubleshooting:
- If a relay does not activate, check the control signal and power supply connections.
- If the relay activates but the load does not operate, check the load connections and the load itself.
- If the module overheats, ensure proper ventilation and reduce the load current if necessary.
View more about NC4D-P-DC5V on main site